FabDigitFabDigit

Stainless Steel 904L Cold Rolled Hard vs 904L Solution Annealed

Stainless Steel · 904L temper comparison

904L Cold Rolled Hard and 904L Solution Annealed are two conditions of the same stainless steel grade, 904L: Cold Rolled Hard (cold rolled strip/sheet, temper rolled) versus Solution Annealed. The chemistry is identical, so every difference below comes from the condition. 904L Cold Rolled Hard is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 260 MPa (37.7 ksi) for 904L Solution Annealed, about 138% more; tensile strength follows at 820 MPa (119 ksi) vs 590 MPa (85.6 ksi). In exchange, 904L Solution Annealed is the more ductile: elongation 42% versus 15% for 904L Cold Rolled Hard, and 904L Cold Rolled Hard is harder (260 HB vs 155 HB). 904L Solution Annealed runs hotter in service (400°C vs 300°C continuous).

904L Cold Rolled HardChoose it when strength drives the design.

904L Solution AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

904L Cold Rolled Hard vs 904L Solution Annealed: properties

904L Cold Rolled Hard904L Solution Annealed

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

820 MPa119 ksi
590 MPa85.6 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
260 MPa37.7 ksi

Elongation at Break

15%
42%

Reduction in Area

40%
65%

Compressive Strength

630 MPa91.4 ksi
265 MPa38.4 ksi

Shear Strength

505 MPa73.2 ksi
390 MPa56.6 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
240 MPa34.8 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
200 MPa·√m182 ksi·√in

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
180 J133 ft·lbf

Hardness, Brinell

260 HB
155 HB

Hardness, Rockwell B

102 HRB
80 HRB

Hardness, Vickers

275 HV
165 HV

Same in both: Elastic (Young's) Modulus 195 GPa28.3 Msi · Shear Modulus 75 GPa10.9 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,300°C2,372 °F · Liquidus Temperature 1,390°C2,534 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
400°C752 °F

Same in both: Thermal Conductivity 12 W/m·K6.9 BTU/hr·ft·°F · Specific Heat Capacity 450 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.3 µm/m·K8.5 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1×10⁻⁶ Ω·m39.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
82 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Weldability

70 / 100
78 / 100

Formability (cold)

40 / 100
72 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 78 MJ/kg33,534 BTU/lb · Embodied Carbon (primary production) 5.6 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale904L

904L Cold Rolled Hard vs 904L Solution Annealed — frequently asked

Is 904L Cold Rolled Hard stronger than 904L Solution Annealed?

Yes. 904L Cold Rolled Hard has a typical yield strength of 620 MPa (89.9 ksi) against 260 MPa (37.7 ksi) for 904L Solution Annealed — about 138% more. Tensile strength is 820 MPa (119 ksi) vs 590 MPa (85.6 ksi).

Which condition does FabDigit quote by default, Cold Rolled Hard or Solution Annealed?

Solution Annealed is the default 904L condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 904L Cold Rolled Hard or 904L Solution Annealed?

904L Solution Annealed. Its weldability rates very good (78/100) against very good (70/100) for 904L Cold Rolled Hard.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 904L Cold Rolled Hard and 904L Solution Annealed side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.