FabDigitFabDigit

Stainless Steel 40Kh13-A vs 40Kh13-QT200

Stainless Steel · 40Kh13 temper comparison

40Kh13-A and 40Kh13-QT200 are two conditions of the same stainless steel grade, 40Kh13: A (solution annealed) versus QT200 (Q&T 150–300 °C). The chemistry is identical, so every difference below comes from the condition. 40Kh13-QT200 is the stronger of the two: yield strength 1,450 MPa (210 ksi) against 420 MPa (60.9 ksi) for 40Kh13-A, about 3.5 times as much; tensile strength follows at 1,750 MPa (254 ksi) vs 700 MPa (102 ksi). In exchange, 40Kh13-A is the more ductile: elongation 20% versus 5% for 40Kh13-QT200, and 40Kh13-QT200 is harder (500 HB vs 200 HB). 40Kh13-A runs hotter in service (550°C vs 250°C continuous). On the shop floor, 40Kh13-A machines more easily (fair vs not recommended) and 40Kh13-A welds better (poor vs not recommended).

40Kh13-AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

40Kh13-QT200Choose it when strength drives the design.

40Kh13-A vs 40Kh13-QT200: properties

40Kh13-A40Kh13-QT200

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
1,750 MPa254 ksi

Yield Strength (0.2% offset)

420 MPa60.9 ksi
1,450 MPa210 ksi

Elongation at Break

20%
5%

Reduction in Area

45%
15%

Compressive Strength

720 MPa104 ksi
2,200 MPa319 ksi

Shear Strength

430 MPa62.4 ksi
1,050 MPa152 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
750 MPa109 ksi

Fracture Toughness (K_IC)

60 MPa·√m54.6 ksi·√in
22 MPa·√m20 ksi·√in

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

200 HB
500 HB

Hardness, Vickers

210 HV
540 HV

Same in both: Elastic (Young's) Modulus 215 GPa31.2 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28 · Hardness, Rockwell B 94 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.68 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

550°C1,022 °F
250°C482 °F

Same in both: Thermal Conductivity 28.5 W/m·K16.5 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.4 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

40 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
10 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
10%

Weldability

25 / 100
10 / 100

Polishability

70 / 100
92 / 100

Same in both: Formability (cold) 40 / 100 · Castability 40 / 100 · Brazeability / Solderability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 4.5 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale40Kh13

40Kh13-A vs 40Kh13-QT200 — frequently asked

Is 40Kh13-QT200 stronger than 40Kh13-A?

Yes. 40Kh13-QT200 has a typical yield strength of 1,450 MPa (210 ksi) against 420 MPa (60.9 ksi) for 40Kh13-A — about 3.5 times as much. Tensile strength is 1,750 MPa (254 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, A or QT200?

A is the default 40Kh13 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 40Kh13-A or 40Kh13-QT200?

40Kh13-A. Its machinability rates fair (45/100) against not recommended (10/100) for 40Kh13-QT200; for welding the order is 40Kh13-A first (poor, 25/100) then 40Kh13-QT200 (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 40Kh13-A and 40Kh13-QT200 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.