317L Cold Drawn and 317L Solution Annealed are two conditions of the same stainless steel grade, 317L: Cold Drawn versus Solution Annealed. The chemistry is identical, so every difference below comes from the condition. 317L Cold Drawn is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 265 MPa (38.4 ksi) for 317L Solution Annealed, about 70% more; tensile strength follows at 690 MPa (100 ksi) vs 580 MPa (84.1 ksi). In exchange, 317L Solution Annealed is the more ductile: elongation 50% versus 30% for 317L Cold Drawn, and 317L Cold Drawn is harder (210 HB vs 155 HB). 317L Solution Annealed runs hotter in service (870°C vs 425°C continuous).

317L Cold DrawnChoose it when strength drives the design.

317L Solution AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

317L Cold Drawn vs 317L Solution Annealed: properties

317L Cold Drawn317L Solution Annealed

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

690 MPa100 ksi
580 MPa84.1 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
265 MPa38.4 ksi

Elongation at Break

30%
50%

Reduction in Area

50%
65%

Shear Strength

455 MPa66 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

310 MPa45 ksi
250 MPa36.3 ksi

Fracture Toughness (K_IC)

150 MPa·√m137 ksi·√in
200 MPa·√m182 ksi·√in

Charpy V-Notch Impact (RT)

110 J81.1 ft·lbf
180 J133 ft·lbf

Hardness, Brinell

210 HB
155 HB

Hardness, Rockwell B

96 HRB
82 HRB

Hardness, Vickers

220 HV
165 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.98 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,375°C2,507 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

425°C797 °F
870°C1,598 °F

Same in both: Thermal Conductivity 14.2 W/m·K8.2 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16 µm/m·K8.9 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 7.9×10⁻⁷ Ω·m31.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
45%

Weldability

88 / 100
90 / 100

Formability (cold)

55 / 100
82 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 65 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 140 L/kg16.8 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale317L

317L Cold Drawn vs 317L Solution Annealed — frequently asked

Is 317L Cold Drawn stronger than 317L Solution Annealed?

Yes. 317L Cold Drawn has a typical yield strength of 450 MPa (65.3 ksi) against 265 MPa (38.4 ksi) for 317L Solution Annealed — about 70% more. Tensile strength is 690 MPa (100 ksi) vs 580 MPa (84.1 ksi).

Which condition does FabDigit quote by default, Cold Drawn or Solution Annealed?

Solution Annealed is the default 317L condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 317L Cold Drawn over 317L Solution Annealed?

Pick 317L Cold Drawn when strength drives the design. Pick 317L Solution Annealed when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 317L Cold Drawn and 317L Solution Annealed side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.