FabDigitFabDigit

Stainless Steel 317L Annealed vs 317L Cold Drawn

Stainless Steel · 317L temper comparison

317L Annealed and 317L Cold Drawn are two conditions of the same stainless steel grade, 317L: Annealed versus Cold Drawn. The chemistry is identical, so every difference below comes from the condition. 317L Cold Drawn is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 260 MPa (37.7 ksi) for 317L Annealed, about 73% more; tensile strength follows at 690 MPa (100 ksi) vs 575 MPa (83.4 ksi). In exchange, 317L Annealed is the more ductile: elongation 50% versus 30% for 317L Cold Drawn, and 317L Cold Drawn is harder (210 HB vs 150 HB). 317L Annealed runs hotter in service (870°C vs 425°C continuous).

317L AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

317L Cold DrawnChoose it when strength drives the design.

317L Annealed vs 317L Cold Drawn: properties

317L Annealed317L Cold Drawn

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

575 MPa83.4 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

260 MPa37.7 ksi
450 MPa65.3 ksi

Elongation at Break

50%
30%

Reduction in Area

65%
50%

Shear Strength

400 MPa58 ksi
455 MPa66 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
310 MPa45 ksi

Fracture Toughness (K_IC)

200 MPa·√m182 ksi·√in
150 MPa·√m137 ksi·√in

Charpy V-Notch Impact (RT)

180 J133 ft·lbf
110 J81.1 ft·lbf

Hardness, Brinell

150 HB
210 HB

Hardness, Rockwell B

80 HRB
96 HRB

Hardness, Vickers

160 HV
220 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.98 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,375°C2,507 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

870°C1,598 °F
425°C797 °F

Same in both: Thermal Conductivity 14.2 W/m·K8.2 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16 µm/m·K8.9 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 7.9×10⁻⁷ Ω·m31.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

80 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
50%

Weldability

90 / 100
88 / 100

Formability (cold)

84 / 100
55 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 65 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 140 L/kg16.8 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale317L

317L Annealed vs 317L Cold Drawn — frequently asked

Is 317L Cold Drawn stronger than 317L Annealed?

Yes. 317L Cold Drawn has a typical yield strength of 450 MPa (65.3 ksi) against 260 MPa (37.7 ksi) for 317L Annealed — about 73% more. Tensile strength is 690 MPa (100 ksi) vs 575 MPa (83.4 ksi).

Which condition does FabDigit quote by default, Annealed or Cold Drawn?

Solution Annealed is the default 317L condition in the FabDigit quote flow (neither Annealed nor Cold Drawn). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 317L Annealed over 317L Cold Drawn?

Pick 317L Annealed when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 317L Cold Drawn when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 317L Annealed and 317L Cold Drawn side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.