FabDigitFabDigit

Stainless Steel 303Se Annealed vs 303Se Cold Drawn High Tensile

Stainless Steel · 303Se temper comparison

303Se Annealed and 303Se Cold Drawn High Tensile are two conditions of the same stainless steel grade, 303Se: Annealed versus Cold Drawn High Tensile (heavily cold-drawn bar). The chemistry is identical, so every difference below comes from the condition. 303Se Cold Drawn High Tensile is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 240 MPa (34.8 ksi) for 303Se Annealed, about 158% more; tensile strength follows at 860 MPa (125 ksi) vs 620 MPa (89.9 ksi). In exchange, 303Se Annealed is the more ductile: elongation 50% versus 16% for 303Se Cold Drawn High Tensile, and 303Se Cold Drawn High Tensile is harder (270 HB vs 160 HB).

303Se AnnealedChoose it when the part is bent, formed or impact-loaded.

303Se Cold Drawn High TensileChoose it when strength drives the design.

303Se Annealed vs 303Se Cold Drawn High Tensile: properties

303Se Annealed303Se Cold Drawn High Tensile

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
860 MPa125 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
620 MPa89.9 ksi

Elongation at Break

50%
16%

Reduction in Area

55%
35%

Compressive Strength

240 MPa34.8 ksi
415 MPa60.2 ksi

Shear Strength

430 MPa62.4 ksi
560 MPa81.2 ksi

Fatigue Strength (Endurance Limit)

255 MPa37 ksi
340 MPa49.3 ksi

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

160 HB
270 HB

Hardness, Rockwell B

84 HRB
98 HRB

Hardness, Vickers

168 HV
285 HV

Same in both: Elastic (Young's) Modulus 193 GPa28 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.3 · Fracture Toughness (K_IC) 110 MPa·√m100 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,425°C2,597 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 16.2 W/m·K9.4 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.3 µm/m·K9.6 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Max Service Temperature (continuous) 760°C1,400 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.4 % IACS · Electrical Resistivity 7.2×10⁻⁷ Ω·m28.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

57 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.08 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

82 / 100
85 / 100

Machinability Rating (AISI 1212 = 100 %)

78%
75%

Formability (cold)

55 / 100
25 / 100

Same in both: Weldability 22 / 100 · Brazeability / Solderability 50 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 54 MJ/kg23,216 BTU/lb · Embodied Carbon (primary production) 4.8 kg CO₂/kg · Embodied Water 180 L/kg21.6 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale303Se

303Se Annealed vs 303Se Cold Drawn High Tensile — frequently asked

Is 303Se Cold Drawn High Tensile stronger than 303Se Annealed?

Yes. 303Se Cold Drawn High Tensile has a typical yield strength of 620 MPa (89.9 ksi) against 240 MPa (34.8 ksi) for 303Se Annealed — about 158% more. Tensile strength is 860 MPa (125 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, Annealed or Cold Drawn High Tensile?

Cold Drawn is the default 303Se condition in the FabDigit quote flow (neither Annealed nor Cold Drawn High Tensile). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 303Se Annealed over 303Se Cold Drawn High Tensile?

Pick 303Se Annealed when the part is bent, formed or impact-loaded. Pick 303Se Cold Drawn High Tensile when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 303Se Annealed and 303Se Cold Drawn High Tensile side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.