FabDigitFabDigit

Stainless Steel 253 MA-CD vs 253 MA Forged+SA

Stainless Steel · 253 MA temper comparison

253 MA-CD and 253 MA Forged+SA are two conditions of the same stainless steel grade, 253 MA: CD (cold drawn) versus Forged+SA (forged and solution annealed). The chemistry is identical, so every difference below comes from the condition. 253 MA-CD is the stronger of the two: yield strength 560 MPa (81.2 ksi) against 340 MPa (49.3 ksi) for 253 MA Forged+SA, about 65% more; tensile strength follows at 800 MPa (116 ksi) vs 660 MPa (95.7 ksi). In exchange, 253 MA Forged+SA is the more ductile: elongation 42% versus 25% for 253 MA-CD, and 253 MA-CD is harder (250 HB vs 185 HB).

253 MA-CDChoose it when strength drives the design.

253 MA Forged+SAChoose it when the part is bent, formed or impact-loaded.

253 MA-CD vs 253 MA Forged+SA: properties

253 MA-CD253 MA Forged+SA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

800 MPa116 ksi
660 MPa95.7 ksi

Yield Strength (0.2% offset)

560 MPa81.2 ksi
340 MPa49.3 ksi

Elongation at Break

25%
42%

Reduction in Area

45%
58%

Compressive Strength

570 MPa82.7 ksi
340 MPa49.3 ksi

Shear Strength

480 MPa69.6 ksi
410 MPa59.5 ksi

Fatigue Strength (Endurance Limit)

320 MPa46.4 ksi
260 MPa37.7 ksi

Fracture Toughness (K_IC)

140 MPa·√m127 ksi·√in
170 MPa·√m155 ksi·√in

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
85 J62.7 ft·lbf

Hardness, Brinell

250 HB
185 HB

Hardness, Rockwell B

100 HRB
90 HRB

Hardness, Vickers

263 HV
195 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,370°C2,498 °F · Liquidus Temperature 1,425°C2,597 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 1,100°C2,012 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2 % IACS · Electrical Resistivity 8.5×10⁻⁷ Ω·m33.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

64 / 100
66 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
36 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
33%

Weldability

68 / 100
72 / 100

Formability (cold)

35 / 100
48 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 56 MJ/kg24,076 BTU/lb · Embodied Carbon (primary production) 5.6 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale253 MA

253 MA-CD vs 253 MA Forged+SA — frequently asked

Is 253 MA-CD stronger than 253 MA Forged+SA?

Yes. 253 MA-CD has a typical yield strength of 560 MPa (81.2 ksi) against 340 MPa (49.3 ksi) for 253 MA Forged+SA — about 65% more. Tensile strength is 800 MPa (116 ksi) vs 660 MPa (95.7 ksi).

Which condition does FabDigit quote by default, CD or Forged+SA?

Annealed is the default 253 MA condition in the FabDigit quote flow (neither CD nor Forged+SA). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 253 MA-CD or 253 MA Forged+SA?

253 MA-CD, by a small margin. Both rate fair for machinability — 42/100 against 36/100 for 253 MA Forged+SA.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 253 MA-CD and 253 MA Forged+SA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.