FabDigitFabDigit

Stainless Steel 253 MA Annealed vs 253 MA-CD

Stainless Steel · 253 MA temper comparison

253 MA Annealed and 253 MA-CD are two conditions of the same stainless steel grade, 253 MA: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 253 MA-CD is the stronger of the two: yield strength 560 MPa (81.2 ksi) against 350 MPa (50.8 ksi) for 253 MA Annealed, about 60% more; tensile strength follows at 800 MPa (116 ksi) vs 680 MPa (98.6 ksi). In exchange, 253 MA Annealed is the more ductile: elongation 45% versus 25% for 253 MA-CD, and 253 MA-CD is harder (250 HB vs 180 HB).

253 MA AnnealedChoose it when the part is bent, formed or impact-loaded.

253 MA-CDChoose it when strength drives the design.

253 MA Annealed vs 253 MA-CD: properties

253 MA Annealed253 MA-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

680 MPa98.6 ksi
800 MPa116 ksi

Yield Strength (0.2% offset)

350 MPa50.8 ksi
560 MPa81.2 ksi

Elongation at Break

45%
25%

Reduction in Area

60%
45%

Compressive Strength

350 MPa50.8 ksi
570 MPa82.7 ksi

Shear Strength

420 MPa60.9 ksi
480 MPa69.6 ksi

Fatigue Strength (Endurance Limit)

270 MPa39.2 ksi
320 MPa46.4 ksi

Fracture Toughness (K_IC)

180 MPa·√m164 ksi·√in
140 MPa·√m127 ksi·√in

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

180 HB
250 HB

Hardness, Rockwell B

89 HRB
100 HRB

Hardness, Vickers

190 HV
263 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,370°C2,498 °F · Liquidus Temperature 1,425°C2,597 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 1,100°C2,012 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2 % IACS · Electrical Resistivity 8.5×10⁻⁷ Ω·m33.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
64 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
40%

Weldability

72 / 100
68 / 100

Formability (cold)

55 / 100
35 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 56 MJ/kg24,076 BTU/lb · Embodied Carbon (primary production) 5.6 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale253 MA

253 MA Annealed vs 253 MA-CD — frequently asked

Is 253 MA-CD stronger than 253 MA Annealed?

Yes. 253 MA-CD has a typical yield strength of 560 MPa (81.2 ksi) against 350 MPa (50.8 ksi) for 253 MA Annealed — about 60% more. Tensile strength is 800 MPa (116 ksi) vs 680 MPa (98.6 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

Annealed is the default 253 MA condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 253 MA Annealed over 253 MA-CD?

Pick 253 MA Annealed when the part is bent, formed or impact-loaded. Pick 253 MA-CD when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 253 MA Annealed and 253 MA-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.