FabDigitFabDigit

Stainless Steel 17-7 PH Condition A vs 17-7 PH-T

Stainless Steel · 17-7 PH temper comparison

17-7 PH Condition A and 17-7 PH-T are two conditions of the same stainless steel grade, 17-7 PH: Condition A (solution annealed) versus T (condition T). The chemistry is identical, so every difference below comes from the condition. 17-7 PH-T is the stronger of the two: yield strength 760 MPa (110 ksi) against 276 MPa (40 ksi) for 17-7 PH Condition A, about 175% more; tensile strength follows at 1,035 MPa (150 ksi) vs 896 MPa (130 ksi). In exchange, 17-7 PH Condition A is the more ductile: elongation 35% versus 10% for 17-7 PH-T, and 17-7 PH-T is harder (300 HB vs 175 HB). On the shop floor, 17-7 PH Condition A welds better (good vs fair).

17-7 PH Condition AChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

17-7 PH-TChoose it when strength drives the design.

17-7 PH Condition A vs 17-7 PH-T: properties

17-7 PH Condition A17-7 PH-T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

896 MPa130 ksi
1,035 MPa150 ksi

Yield Strength (0.2% offset)

276 MPa40 ksi
760 MPa110 ksi

Elongation at Break

35%
10%

Reduction in Area

55%
40%

Shear Strength

585 MPa84.8 ksi
655 MPa95 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
450 MPa65.3 ksi

Charpy V-Notch Impact (RT)

100 J73.8 ft·lbf
27 J19.9 ft·lbf

Hardness, Brinell

175 HB
300 HB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 152 GPa22 Msi · Poisson's Ratio 0.28 · Hardness, Rockwell B 85 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.81 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 16.4 W/m·K9.5 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11 µm/m·K6.1 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -73°C-99 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
30%

Weldability

55 / 100
35 / 100

Formability (cold)

70 / 100
35 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 5 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale17-7 PH

17-7 PH Condition A vs 17-7 PH-T — frequently asked

Is 17-7 PH-T stronger than 17-7 PH Condition A?

Yes. 17-7 PH-T has a typical yield strength of 760 MPa (110 ksi) against 276 MPa (40 ksi) for 17-7 PH Condition A — about 175% more. Tensile strength is 1,035 MPa (150 ksi) vs 896 MPa (130 ksi).

Which condition does FabDigit quote by default, Condition A or T?

Condition A is the default 17-7 PH condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 17-7 PH Condition A or 17-7 PH-T?

17-7 PH Condition A. Its weldability rates good (55/100) against fair (35/100) for 17-7 PH-T.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 17-7 PH Condition A and 17-7 PH-T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.