Stainless Steel · 17-7 PH temper comparison

17-7 PH Condition A and 17-7 PH-RH950 are two conditions of the same stainless steel grade, 17-7 PH: Condition A (solution annealed) versus RH950 (austenite conditioned (955 °C) + refrigerated (−73 °C) + aged 510 °C /…). The chemistry is identical, so every difference below comes from the condition. 17-7 PH-RH950 is the stronger of the two: yield strength 1,310 MPa (190 ksi) against 276 MPa (40 ksi) for 17-7 PH Condition A, about 4.7 times as much; tensile strength follows at 1,450 MPa (210 ksi) vs 896 MPa (130 ksi). In exchange, 17-7 PH Condition A is the more ductile: elongation 35% versus 6% for 17-7 PH-RH950. On the shop floor, 17-7 PH Condition A welds better (good vs poor).

17-7 PH Condition AChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

17-7 PH-RH950Choose it when strength drives the design.

17-7 PH Condition A vs 17-7 PH-RH950: properties

17-7 PH Condition A17-7 PH-RH950

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
204 GPa29.6 Msi

Tensile Strength (Ultimate)

896 MPa130 ksi
1,450 MPa210 ksi

Yield Strength (0.2% offset)

276 MPa40 ksi
1,310 MPa190 ksi

Elongation at Break

35%
6%

Reduction in Area

55%
22%

Shear Strength

585 MPa84.8 ksi
880 MPa128 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
655 MPa95 ksi

Charpy V-Notch Impact (RT)

100 J73.8 ft·lbf
14 J10.3 ft·lbf

Same in both: Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 152 GPa22 Msi · Poisson's Ratio 0.28 · Hardness, Brinell 175 HB · Hardness, Rockwell B 85 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.81 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 16.4 W/m·K9.5 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11 µm/m·K6.1 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -73°C-99 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

35%
20%

Weldability

55 / 100
30 / 100

Formability (cold)

70 / 100
10 / 100

Same in both: Machinability 32 / 100 · Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 5 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale17-7 PH

17-7 PH Condition A vs 17-7 PH-RH950 — frequently asked

Is 17-7 PH-RH950 stronger than 17-7 PH Condition A?

Yes. 17-7 PH-RH950 has a typical yield strength of 1,310 MPa (190 ksi) against 276 MPa (40 ksi) for 17-7 PH Condition A — about 4.7 times as much. Tensile strength is 1,450 MPa (210 ksi) vs 896 MPa (130 ksi).

Which condition does FabDigit quote by default, Condition A or RH950?

Condition A is the default 17-7 PH condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 17-7 PH Condition A or 17-7 PH-RH950?

17-7 PH Condition A. Its weldability rates good (55/100) against poor (30/100) for 17-7 PH-RH950.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 17-7 PH Condition A and 17-7 PH-RH950 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.