FabDigitFabDigit

Stainless Steel 1.4980-CD vs 1.4980-STA

Stainless Steel · 1.4980 temper comparison

1.4980-CD and 1.4980-STA are two conditions of the same stainless steel grade, 1.4980: CD (cold drawn) versus STA (solution treated and aged). The chemistry is identical, so every difference below comes from the condition. 1.4980-STA is the stronger of the two: tensile strength 1,000 MPa (145 ksi) against 900 MPa (131 ksi) for 1.4980-CD, about 11% more. 1.4980-STA is the more ductile: elongation 25% versus 20% for 1.4980-CD, and 1.4980-STA is harder (300 HB vs 255 HB). 1.4980-STA runs hotter in service (700°C vs 500°C continuous).

1.4980-STAChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1.4980-CD vs 1.4980-STA: properties

1.4980-CD1.4980-STA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
201 GPa29.2 Msi

Tensile Strength (Ultimate)

900 MPa131 ksi
1,000 MPa145 ksi

Yield Strength (0.2% offset)

690 MPa100 ksi
700 MPa102 ksi

Elongation at Break

20%
25%

Reduction in Area

35%
40%

Compressive Strength

700 MPa102 ksi
730 MPa106 ksi

Shear Strength

560 MPa81.2 ksi
620 MPa89.9 ksi

Fatigue Strength (Endurance Limit)

420 MPa60.9 ksi
480 MPa69.6 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
110 MPa·√m100 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

255 HB
300 HB

Hardness, Rockwell C

25 HRC
31 HRC

Hardness, Vickers

268 HV
315 HV

Same in both: Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 176 GPa25.5 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 7.92 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,370°C2,498 °F · Liquidus Temperature 1,430°C2,606 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

500°C932 °F
700°C1,292 °F

Same in both: Thermal Conductivity 12.6 W/m·K7.3 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.4 µm/m·K9.1 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.9 % IACS · Electrical Resistivity 9.1×10⁻⁷ Ω·m35.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
20 / 100

Machinability Rating (AISI 1212 = 100 %)

19%
16%

Formability (cold)

35 / 100
30 / 100

Same in both: Weldability 45 / 100 · Brazeability / Solderability 55 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 80 MJ/kg34,394 BTU/lb · Embodied Carbon (primary production) 5.8 kg CO₂/kg · Embodied Water 120 L/kg14.4 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4980

1.4980-CD vs 1.4980-STA — frequently asked

Is 1.4980-STA stronger than 1.4980-CD?

Yes. 1.4980-STA has a typical tensile strength of 1,000 MPa (145 ksi) against 900 MPa (131 ksi) for 1.4980-CD — about 11% more.

Which condition does FabDigit quote by default, CD or STA?

STA is the default 1.4980 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1.4980-CD over 1.4980-STA?

Pick 1.4980-STA when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4980-CD and 1.4980-STA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.