FabDigitFabDigit

Stainless Steel 1.4980-CD vs 1.4980-ST

Stainless Steel · 1.4980 temper comparison

1.4980-CD and 1.4980-ST are two conditions of the same stainless steel grade, 1.4980: CD (cold drawn) versus ST (solution annealed). The chemistry is identical, so every difference below comes from the condition. 1.4980-CD is the stronger of the two: yield strength 690 MPa (100 ksi) against 310 MPa (45 ksi) for 1.4980-ST, about 123% more; tensile strength follows at 900 MPa (131 ksi) vs 690 MPa (100 ksi). In exchange, 1.4980-ST is the more ductile: elongation 45% versus 20% for 1.4980-CD, and 1.4980-CD is harder (255 HB vs 170 HB). 1.4980-ST runs hotter in service (600°C vs 500°C continuous). On the shop floor, 1.4980-ST welds better (good vs fair).

1.4980-CDChoose it when strength drives the design.

1.4980-STChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4980-CD vs 1.4980-ST: properties

1.4980-CD1.4980-ST

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
201 GPa29.2 Msi

Tensile Strength (Ultimate)

900 MPa131 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

690 MPa100 ksi
310 MPa45 ksi

Elongation at Break

20%
45%

Reduction in Area

35%
55%

Compressive Strength

700 MPa102 ksi
730 MPa106 ksi

Shear Strength

560 MPa81.2 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

420 MPa60.9 ksi
300 MPa43.5 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
110 MPa·√m100 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
120 J88.5 ft·lbf

Hardness, Brinell

255 HB
170 HB

Hardness, Rockwell C

25 HRC
31 HRC

Hardness, Vickers

268 HV
180 HV

Same in both: Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 176 GPa25.5 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 7.92 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,370°C2,498 °F · Liquidus Temperature 1,430°C2,606 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

500°C932 °F
600°C1,112 °F

Same in both: Thermal Conductivity 12.6 W/m·K7.3 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.4 µm/m·K9.1 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.9 % IACS · Electrical Resistivity 9.1×10⁻⁷ Ω·m35.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

19%
22%

Weldability

45 / 100
60 / 100

Formability (cold)

35 / 100
62 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 80 MJ/kg34,394 BTU/lb · Embodied Carbon (primary production) 5.8 kg CO₂/kg · Embodied Water 120 L/kg14.4 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4980

1.4980-CD vs 1.4980-ST — frequently asked

Is 1.4980-CD stronger than 1.4980-ST?

Yes. 1.4980-CD has a typical yield strength of 690 MPa (100 ksi) against 310 MPa (45 ksi) for 1.4980-ST — about 123% more. Tensile strength is 900 MPa (131 ksi) vs 690 MPa (100 ksi).

Which condition does FabDigit quote by default, CD or ST?

STA is the default 1.4980 condition in the FabDigit quote flow (neither CD nor ST). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 1.4980-CD or 1.4980-ST?

1.4980-ST. Its weldability rates good (60/100) against fair (45/100) for 1.4980-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4980-CD and 1.4980-ST side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.