FabDigitFabDigit

Stainless Steel 1.4919-CD vs 1.4919 CW-HH

Stainless Steel · 1.4919 temper comparison

1.4919-CD and 1.4919 CW-HH are two conditions of the same stainless steel grade, 1.4919: CD (cold drawn) versus CW-HH (cold worked, half hard tube/strip). The chemistry is identical, so every difference below comes from the condition. 1.4919 CW-HH is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 480 MPa (69.6 ksi) for 1.4919-CD, about 29% more; tensile strength follows at 850 MPa (123 ksi) vs 700 MPa (102 ksi). In exchange, 1.4919-CD is the more ductile: elongation 25% versus 15% for 1.4919 CW-HH, and 1.4919 CW-HH is harder (260 HB vs 220 HB). 1.4919-CD runs hotter in service (450°C vs 400°C continuous).

1.4919-CDChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4919 CW-HHChoose it when strength drives the design.

1.4919-CD vs 1.4919 CW-HH: properties

1.4919-CD1.4919 CW-HH

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
850 MPa123 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
620 MPa89.9 ksi

Elongation at Break

25%
15%

Reduction in Area

50%
40%

Compressive Strength

480 MPa69.6 ksi
620 MPa89.9 ksi

Shear Strength

450 MPa65.3 ksi
550 MPa79.8 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
360 MPa52.2 ksi

Fracture Toughness (K_IC)

150 MPa·√m137 ksi·√in
120 MPa·√m109 ksi·√in

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

220 HB
260 HB

Hardness, Rockwell B

96 HRB
100 HRB

Hardness, Vickers

232 HV
272 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 166 GPa24.1 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.98 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,390°C2,534 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

450°C842 °F
400°C752 °F

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16 µm/m·K8.9 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.3 % IACS
2.2 % IACS

Electrical Resistivity

7.5×10⁻⁷ Ω·m29.5 µΩ·in
7.6×10⁻⁷ Ω·m29.9 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

68 / 100
66 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
44 / 100

Weldability

65 / 100
62 / 100

Formability (cold)

45 / 100
30 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 40% · Brazeability / Solderability 60 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 5 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4919

1.4919-CD vs 1.4919 CW-HH — frequently asked

Is 1.4919 CW-HH stronger than 1.4919-CD?

Yes. 1.4919 CW-HH has a typical yield strength of 620 MPa (89.9 ksi) against 480 MPa (69.6 ksi) for 1.4919-CD — about 29% more. Tensile strength is 850 MPa (123 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, CD or CW-HH?

AT is the default 1.4919 condition in the FabDigit quote flow (neither CD nor CW-HH). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1.4919-CD over 1.4919 CW-HH?

Pick 1.4919-CD when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 1.4919 CW-HH when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4919-CD and 1.4919 CW-HH side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.