FabDigitFabDigit

Stainless Steel 1.4905-A vs 1.4905-AW

Stainless Steel · 1.4905 temper comparison

1.4905-A and 1.4905-AW are two conditions of the same stainless steel grade, 1.4905: A (solution annealed) versus AW (as-welded deposit). The chemistry is identical, so every difference below comes from the condition. 1.4905-AW is the stronger of the two: yield strength 800 MPa (116 ksi) against 400 MPa (58 ksi) for 1.4905-A, about 100% more; tensile strength follows at 1,000 MPa (145 ksi) vs 620 MPa (89.9 ksi). In exchange, 1.4905-A is the more ductile: elongation 25% versus 10% for 1.4905-AW, and 1.4905-AW is harder (375 HB vs 200 HB). 1.4905-AW runs hotter in service (600°C vs 450°C continuous). On the shop floor, 1.4905-A machines more easily (fair vs not recommended) and 1.4905-A welds better (fair vs poor).

1.4905-AChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

1.4905-AWChoose it when strength drives the design, or when the part sees heat.

1.4905-A vs 1.4905-AW: properties

1.4905-A1.4905-AW

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

218 GPa31.6 Msi
216 GPa31.3 Msi

Tensile Strength (Ultimate)

620 MPa89.9 ksi
1,000 MPa145 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
800 MPa116 ksi

Elongation at Break

25%
10%

Reduction in Area

62%
35%

Compressive Strength

530 MPa76.9 ksi
820 MPa119 ksi

Shear Strength

420 MPa60.9 ksi
620 MPa89.9 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
300 MPa43.5 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
40 MPa·√m36.4 ksi·√in

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

200 HB
375 HB

Hardness, Rockwell C

20 HRC
40 HRC

Hardness, Vickers

210 HV
400 HV

Same in both: Shear Modulus 84 GPa12.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.75 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

26 W/m·K15 BTU/hr·ft·°F
25 W/m·K14.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

450°C842 °F
600°C1,112 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3 % IACS
2.8 % IACS

Electrical Resistivity

5.8×10⁻⁷ Ω·m22.8 µΩ·in
6.2×10⁻⁷ Ω·m24.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

30 / 100
28 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.4 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
14 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
17%

Weldability

40 / 100
25 / 100

Formability (cold)

35 / 100
5 / 100

Same in both: Brazeability / Solderability 30 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 36 MJ/kg15,477 BTU/lb · Embodied Carbon (primary production) 2.9 kg CO₂/kg · Embodied Water 70 L/kg8.4 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4905

1.4905-A vs 1.4905-AW — frequently asked

Is 1.4905-AW stronger than 1.4905-A?

Yes. 1.4905-AW has a typical yield strength of 800 MPa (116 ksi) against 400 MPa (58 ksi) for 1.4905-A — about 100% more. Tensile strength is 1,000 MPa (145 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, A or AW?

NT is the default 1.4905 condition in the FabDigit quote flow (neither A nor AW). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4905-A or 1.4905-AW?

1.4905-A. Its machinability rates fair (45/100) against not recommended (14/100) for 1.4905-AW; for welding the order is 1.4905-A first (fair, 40/100) then 1.4905-AW (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4905-A and 1.4905-AW side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.