FabDigitFabDigit

Stainless Steel 1.4845 Annealed vs 1.4845-CD

Stainless Steel · 1.4845 temper comparison

1.4845 Annealed and 1.4845-CD are two conditions of the same stainless steel grade, 1.4845: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 1.4845-CD is the stronger of the two: yield strength 420 MPa (60.9 ksi) against 240 MPa (34.8 ksi) for 1.4845 Annealed, about 75% more; tensile strength follows at 680 MPa (98.6 ksi) vs 560 MPa (81.2 ksi). In exchange, 1.4845 Annealed is the more ductile: elongation 45% versus 30% for 1.4845-CD, and 1.4845-CD is harder (200 HB vs 150 HB). 1.4845 Annealed runs hotter in service (1,150°C vs 870°C continuous).

1.4845 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4845-CDChoose it when strength drives the design.

1.4845 Annealed vs 1.4845-CD: properties

1.4845 Annealed1.4845-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

560 MPa81.2 ksi
680 MPa98.6 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
420 MPa60.9 ksi

Elongation at Break

45%
30%

Reduction in Area

60%
50%

Shear Strength

400 MPa58 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
290 MPa42.1 ksi

Fracture Toughness (K_IC)

200 MPa·√m182 ksi·√in
170 MPa·√m155 ksi·√in

Charpy V-Notch Impact (RT)

160 J118 ft·lbf
110 J81.1 ft·lbf

Hardness, Brinell

150 HB
200 HB

Hardness, Rockwell B

85 HRB
94 HRB

Hardness, Vickers

160 HV
210 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 166 GPa24.1 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

1,150°C2,102 °F
870°C1,598 °F

Same in both: Thermal Conductivity 14.2 W/m·K8.2 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.9 µm/m·K8.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 7.8×10⁻⁷ Ω·m30.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

68 / 100
66 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.08 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
45%

Weldability

65 / 100
60 / 100

Formability (cold)

72 / 100
50 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 78 MJ/kg33,534 BTU/lb · Embodied Carbon (primary production) 6 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4845

1.4845 Annealed vs 1.4845-CD — frequently asked

Is 1.4845-CD stronger than 1.4845 Annealed?

Yes. 1.4845-CD has a typical yield strength of 420 MPa (60.9 ksi) against 240 MPa (34.8 ksi) for 1.4845 Annealed — about 75% more. Tensile strength is 680 MPa (98.6 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

Annealed is the default 1.4845 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4845 Annealed or 1.4845-CD?

1.4845-CD. Its machinability rates fair (38/100) against poor (33/100) for 1.4845 Annealed; for welding the order is 1.4845 Annealed first (good, 65/100) then 1.4845-CD (good, 60/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4845 Annealed and 1.4845-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.