FabDigitFabDigit

Stainless Steel 1.4563-AT vs 1.4563-CD

Stainless Steel · 1.4563 temper comparison

1.4563-AT and 1.4563-CD are two conditions of the same stainless steel grade, 1.4563: AT (solution annealed and quenched) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 1.4563-CD is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 330 MPa (47.9 ksi) for 1.4563-AT, about 88% more; tensile strength follows at 870 MPa (126 ksi) vs 700 MPa (102 ksi). In exchange, 1.4563-AT is the more ductile: elongation 50% versus 25% for 1.4563-CD, and 1.4563-CD is harder (240 HB vs 170 HB).

1.4563-ATChoose it when the part is bent, formed or impact-loaded.

1.4563-CDChoose it when strength drives the design.

1.4563-AT vs 1.4563-CD: properties

1.4563-AT1.4563-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
870 MPa126 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
620 MPa89.9 ksi

Elongation at Break

50%
25%

Reduction in Area

65%
50%

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
360 MPa52.2 ksi

Charpy V-Notch Impact (RT)

180 J133 ft·lbf
110 J81.1 ft·lbf

Hardness, Brinell

170 HB
240 HB

Hardness, Rockwell B

88 HRB
100 HRB

Same in both: Elastic (Young's) Modulus 195 GPa28.3 Msi · Shear Modulus 75 GPa10.9 Msi · Bulk Modulus 155 GPa22.5 Msi · Poisson's Ratio 0.29 · Shear Strength 430 MPa62.4 ksi · Hardness, Vickers 180 HV

Physical

Density and transition temperatures.

Same in both: Density 8.02 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,320°C2,408 °F · Liquidus Temperature 1,370°C2,498 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 11 W/m·K6.4 BTU/hr·ft·°F · Specific Heat Capacity 450 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 14.5 µm/m·K8.1 µin/in·°F · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1×10⁻⁶ Ω·m39.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

92 / 100
90 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
25 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 75 / 100 · Formability (cold) 65 / 100 · Brazeability / Solderability 45 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 100 MJ/kg42,992 BTU/lb · Embodied Carbon (primary production) 8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4563

1.4563-AT vs 1.4563-CD — frequently asked

Is 1.4563-CD stronger than 1.4563-AT?

Yes. 1.4563-CD has a typical yield strength of 620 MPa (89.9 ksi) against 330 MPa (47.9 ksi) for 1.4563-AT — about 88% more. Tensile strength is 870 MPa (126 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, AT or CD?

AT is the default 1.4563 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1.4563-AT over 1.4563-CD?

Pick 1.4563-AT when the part is bent, formed or impact-loaded. Pick 1.4563-CD when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4563-AT and 1.4563-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.