1.4307 +AT and 1.4307 +CP500 are two conditions of the same stainless steel grade, 1.4307: +AT (solution annealed) versus +CP500 (cold worked to minimum 0.2 % proof strength 500 MPa). The chemistry is identical, so every difference below comes from the condition. 1.4307 +CP500 is the stronger of the two: yield strength 560 MPa (81.2 ksi) against 290 MPa (42.1 ksi) for 1.4307 +AT, about 93% more; tensile strength follows at 760 MPa (110 ksi) vs 580 MPa (84.1 ksi). In exchange, 1.4307 +AT is the more ductile: elongation 55% versus 20% for 1.4307 +CP500, and 1.4307 +CP500 is harder (245 HB vs 150 HB). 1.4307 +AT runs hotter in service (425°C vs 300°C continuous). On the shop floor, 1.4307 +CP500 machines more easily (50 vs 38 out of 100) and 1.4307 +AT welds better (95 vs 85 out of 100).

1.4307 +ATChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4307 +CP500Choose it when strength drives the design, or when the part is machined in volume.

1.4307 +AT vs 1.4307 +CP500: properties

1.4307 +AT1.4307 +CP500

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
195 GPa28.3 Msi

Tensile Strength (Ultimate)

580 MPa84.1 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

290 MPa42.1 ksi
560 MPa81.2 ksi

Elongation at Break

55%
20%

Reduction in Area

70%
48%

Compressive Strength

290 MPa42.1 ksi
560 MPa81.2 ksi

Shear Strength

420 MPa60.9 ksi
530 MPa76.9 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
340 MPa49.3 ksi

Fracture Toughness (K_IC)

200 MPa·√m182 ksi·√in
135 MPa·√m123 ksi·√in

Charpy V-Notch Impact (RT)

180 J133 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

150 HB
245 HB

Hardness, Rockwell B

80 HRB
100 HRB

Hardness, Vickers

160 HV
255 HV

Same in both: Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 145 GPa21 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

425°C797 °F
300°C572 °F

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16 µm/m·K8.9 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.4 % IACS
2.3 % IACS

Electrical Resistivity

7.2×10⁻⁷ Ω·m28.3 µΩ·in
7.4×10⁻⁷ Ω·m29.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
61 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
55%

Weldability

95 / 100
85 / 100

Formability (cold)

92 / 100
55 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 65%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4307

1.4307 +AT vs 1.4307 +CP500 — frequently asked

Is 1.4307 +CP500 stronger than 1.4307 +AT?

Yes. 1.4307 +CP500 has a typical yield strength of 560 MPa (81.2 ksi) against 290 MPa (42.1 ksi) for 1.4307 +AT — about 93% more. Tensile strength is 760 MPa (110 ksi) vs 580 MPa (84.1 ksi).

Which condition does FabDigit quote by default, +AT or +CP500?

+AT is the default 1.4307 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4307 +AT or 1.4307 +CP500?

1.4307 +CP500, by a small margin. Both rate fair for machinability — 50/100 against 38/100 for 1.4307 +AT; for welding the order is 1.4307 +AT first (excellent, 95/100) then 1.4307 +CP500 (excellent, 85/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4307 +AT and 1.4307 +CP500 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.