FabDigitFabDigit

Stainless Steel 1.4035 +A vs 1.4035 +C

Stainless Steel · 1.4035 temper comparison

1.4035 +A and 1.4035 +C are two conditions of the same stainless steel grade, 1.4035: +A (annealed) versus +C (cold drawn). The chemistry is identical, so every difference below comes from the condition. 1.4035 +C is the stronger of the two: yield strength 650 MPa (94.3 ksi) against 400 MPa (58 ksi) for 1.4035 +A, about 63% more; tensile strength follows at 850 MPa (123 ksi) vs 700 MPa (102 ksi). In exchange, 1.4035 +A is the more ductile: elongation 14% versus 8% for 1.4035 +C, and 1.4035 +C is harder (260 HB vs 215 HB). 1.4035 +A runs hotter in service (400°C vs 300°C continuous).

1.4035 +AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4035 +CChoose it when strength drives the design.

1.4035 +A vs 1.4035 +C: properties

1.4035 +A1.4035 +C

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
850 MPa123 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
650 MPa94.3 ksi

Elongation at Break

14%
8%

Reduction in Area

35%
25%

Compressive Strength

420 MPa60.9 ksi
670 MPa97.2 ksi

Shear Strength

430 MPa62.4 ksi
510 MPa74 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
350 MPa50.8 ksi

Fracture Toughness (K_IC)

60 MPa·√m54.6 ksi·√in
50 MPa·√m45.5 ksi·√in

Charpy V-Notch Impact (RT)

15 J11.1 ft·lbf
10 J7.4 ft·lbf

Hardness, Brinell

215 HB
260 HB

Hardness, Rockwell B

96 HRB
102 HRB

Hardness, Vickers

225 HV
272 HV

Same in both: Elastic (Young's) Modulus 215 GPa31.2 Msi · Shear Modulus 82 GPa11.9 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
300°C572 °F

Same in both: Thermal Conductivity 30 W/m·K17.3 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.5 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 3.1 % IACS · Electrical Resistivity 5.5×10⁻⁷ Ω·m21.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

34 / 100
35 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.35 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
72%

Weldability

12 / 100
8 / 100

Formability (cold)

22 / 100
12 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 4.3 kg CO₂/kg · Embodied Water 190 L/kg22.8 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4035

1.4035 +A vs 1.4035 +C — frequently asked

Is 1.4035 +C stronger than 1.4035 +A?

Yes. 1.4035 +C has a typical yield strength of 650 MPa (94.3 ksi) against 400 MPa (58 ksi) for 1.4035 +A — about 63% more. Tensile strength is 850 MPa (123 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, +A or +C?

+A is the default 1.4035 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1.4035 +A over 1.4035 +C?

Pick 1.4035 +A when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 1.4035 +C when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4035 +A and 1.4035 +C side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.