1.4029 +C and 1.4029 +QT (hardened, low temper) are two conditions of the same stainless steel grade, 1.4029: +C (cold drawn) versus +QT (hardened, low temper) (hardened & low-temperature tempered). The chemistry is identical, so every difference below comes from the condition. 1.4029 +QT (hardened, low temper) is the stronger of the two: yield strength 1,350 MPa (196 ksi) against 620 MPa (89.9 ksi) for 1.4029 +C, about 118% more; tensile strength follows at 1,600 MPa (232 ksi) vs 830 MPa (120 ksi). In exchange, 1.4029 +C is the more ductile: elongation 10% versus 3% for 1.4029 +QT (hardened, low temper), and 1.4029 +C is harder (250 HB vs 215 HB). 1.4029 +C runs hotter in service (300°C vs 200°C continuous). On the shop floor, 1.4029 +C machines more easily (good vs poor).

1.4029 +CChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4029 +QT (hardened, low temper)Choose it when strength drives the design.

1.4029 +C vs 1.4029 +QT (hardened, low temper): properties

1.4029 +C1.4029 +QT (hardened, low temper)

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

830 MPa120 ksi
1,600 MPa232 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
1,350 MPa196 ksi

Elongation at Break

10%
3%

Reduction in Area

30%
40%

Compressive Strength

640 MPa92.8 ksi
460 MPa66.7 ksi

Shear Strength

500 MPa72.5 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

350 MPa50.8 ksi
520 MPa75.4 ksi

Fracture Toughness (K_IC)

50 MPa·√m45.5 ksi·√in
22 MPa·√m20 ksi·√in

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
6 J4.4 ft·lbf

Hardness, Brinell

250 HB
215 HB

Hardness, Rockwell B

101 HRB
96 HRB

Hardness, Vickers

262 HV
520 HV

Same in both: Elastic (Young's) Modulus 215 GPa31.2 Msi · Shear Modulus 82 GPa11.9 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
200°C392 °F

Same in both: Thermal Conductivity 30 W/m·K17.3 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.5 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3 % IACS
3.1 % IACS

Electrical Resistivity

5.7×10⁻⁷ Ω·m22.4 µΩ·in
5.5×10⁻⁷ Ω·m21.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

24 / 100
30 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
15 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
15%

Weldability

10 / 100
12 / 100

Formability (cold)

12 / 100
25 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 35 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 40 MJ/kg17,197 BTU/lb · Embodied Carbon (primary production) 3.4 kg CO₂/kg · Embodied Water 120 L/kg14.4 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4029

1.4029 +C vs 1.4029 +QT (hardened, low temper) — frequently asked

Is 1.4029 +QT (hardened, low temper) stronger than 1.4029 +C?

Yes. 1.4029 +QT (hardened, low temper) has a typical yield strength of 1,350 MPa (196 ksi) against 620 MPa (89.9 ksi) for 1.4029 +C — about 118% more. Tensile strength is 1,600 MPa (232 ksi) vs 830 MPa (120 ksi).

Which condition does FabDigit quote by default, +C or +QT (hardened, low temper)?

+A is the default 1.4029 condition in the FabDigit quote flow (neither +C nor +QT (hardened, low temper)). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4029 +C or 1.4029 +QT (hardened, low temper)?

1.4029 +C. Its machinability rates good (68/100) against poor (15/100) for 1.4029 +QT (hardened, low temper).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4029 +C and 1.4029 +QT (hardened, low temper) side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.