FabDigitFabDigit

Solder & Low-Melting Alloy Type 2 Sheet Pewter-F vs Type 2 Sheet Pewter-O

Solder & Low-Melting Alloy · Type 2 Sheet Pewter temper comparison

Type 2 Sheet Pewter-F and Type 2 Sheet Pewter-O are two conditions of the same solder & low-melting alloy grade, Type 2 Sheet Pewter: F (as fabricated) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. Type 2 Sheet Pewter-O is the stronger of the two: yield strength 28 MPa (4.06 ksi) against 26 MPa (3.77 ksi) for Type 2 Sheet Pewter-F, about 8% more; tensile strength follows at 58 MPa (8.41 ksi) vs 50 MPa (7.25 ksi). Type 2 Sheet Pewter-O is the more ductile: elongation 42% versus 35% for Type 2 Sheet Pewter-F, and Type 2 Sheet Pewter-F is harder (20 HB vs 19 HB).

Type 2 Sheet Pewter-OChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

Type 2 Sheet Pewter-F vs Type 2 Sheet Pewter-O: properties

Type 2 Sheet Pewter-FType 2 Sheet Pewter-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

50 MPa7.3 ksi
58 MPa8.4 ksi

Yield Strength (0.2% offset)

26 MPa3.8 ksi
28 MPa4.1 ksi

Elongation at Break

35%
42%

Shear Strength

32 MPa4.6 ksi
36 MPa5.2 ksi

Fatigue Strength (Endurance Limit)

16 MPa2.3 ksi
17 MPa2.5 ksi

Hardness, Brinell

20 HB
19 HB

Same in both: Elastic (Young's) Modulus 45 GPa6.5 Msi · Shear Modulus 17 GPa2.5 Msi · Bulk Modulus 55 GPa8 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 7.28 g/cm³0.26 lb/in³ · Melting Point (Solidus) 244°C471 °F · Liquidus Temperature 295°C563 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

85°C185 °F
90°C194 °F

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 230 J/kg·K0.05 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22 µm/m·K12.2 µin/in·°F · Latent Heat of Fusion 55 J/g23.6 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.5 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

68%
65%

Formability (cold)

80 / 100
98 / 100

Same in both: Weldability 20 / 100 · Castability 90 / 100 · Brazeability / Solderability 95 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 280 MJ/kg120,378 BTU/lb · Embodied Carbon (primary production) 16 kg CO₂/kg · Embodied Water 1,600 L/kg192 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every solder & low-melting alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

125102050891011Density (g/cm³)Yield strength (MPa) — log scaleType 2 Sheet Pewter

Type 2 Sheet Pewter-F vs Type 2 Sheet Pewter-O — frequently asked

Is Type 2 Sheet Pewter-O stronger than Type 2 Sheet Pewter-F?

Yes. Type 2 Sheet Pewter-O has a typical yield strength of 28 MPa (4.06 ksi) against 26 MPa (3.77 ksi) for Type 2 Sheet Pewter-F — about 8% more. Tensile strength is 58 MPa (8.41 ksi) vs 50 MPa (7.25 ksi).

Which condition does FabDigit quote by default, F or O?

CR is the default Type 2 Sheet Pewter condition in the FabDigit quote flow (neither F nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Type 2 Sheet Pewter-F over Type 2 Sheet Pewter-O?

Pick Type 2 Sheet Pewter-O when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Type 2 Sheet Pewter-F and Type 2 Sheet Pewter-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.