Precious Metal PdRu5-H02 vs PdRu5 Stress-relieved
Precious Metal · PdRu5 temper comparison
PdRu5-H02 and PdRu5 Stress-relieved are two conditions of the same precious metal grade, PdRu5: H02 (half hard) versus Stress-relieved. The chemistry is identical, so every difference below comes from the condition. PdRu5 Stress-relieved is the stronger of the two: yield strength 790 MPa (115 ksi) against 600 MPa (87 ksi) for PdRu5-H02, about 32% more; tensile strength follows at 860 MPa (125 ksi) vs 720 MPa (104 ksi). In exchange, PdRu5-H02 is the more ductile: elongation 6% versus 3% for PdRu5 Stress-relieved, and PdRu5 Stress-relieved is harder (209 HB vs 180 HB). PdRu5-H02 runs hotter in service (400°C vs 350°C continuous).
PdRu5-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.
PdRu5 Stress-relievedChoose it when strength drives the design.
PdRu5-H02 vs PdRu5 Stress-relieved: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all precious metal grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all precious metal grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
PdRu5-H02PdRu5 Stress-relieved
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Shear Strength
Fatigue Strength (Endurance Limit)
Hardness, Brinell
Hardness, Rockwell B
Hardness, Vickers
Same in both: Shear Modulus 50 GPa7.3 Msi · Bulk Modulus 195 GPa28.3 Msi · Poisson's Ratio 0.39
Physical
Density and transition temperatures.
Same in both: Density 12.05 g/cm³0.44 lb/in³ · Melting Point (Solidus) 1,575°C2,867 °F · Liquidus Temperature 1,600°C2,912 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 245 J/kg·K0.06 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 157 J/g67.5 BTU/lb · Min Service Temperature -269°C-452 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) 0.2 V · Corrosion Resistance 92 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Weldability
Formability (cold)
Same in both: Machinability 35 / 100 · Machinability Rating (AISI 1212 = 100 %) 30% · Castability 40 / 100 · Brazeability / Solderability 80 / 100 · Polishability 90 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 95,000 MJ/kg4.08×10⁷ BTU/lb · Embodied Carbon (primary production) 3,800 kg CO₂/kg · Typical Recycled Content 55%
Strength versus weight
Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
PdRu5-H02 vs PdRu5 Stress-relieved — frequently asked
Is PdRu5 Stress-relieved stronger than PdRu5-H02?
Yes. PdRu5 Stress-relieved has a typical yield strength of 790 MPa (115 ksi) against 600 MPa (87 ksi) for PdRu5-H02 — about 32% more. Tensile strength is 860 MPa (125 ksi) vs 720 MPa (104 ksi).
Which condition does FabDigit quote by default, H02 or Stress-relieved?
Annealed is the default PdRu5 condition in the FabDigit quote flow (neither H02 nor Stress-relieved). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which welds better, PdRu5-H02 or PdRu5 Stress-relieved?
PdRu5-H02. Its weldability rates good (55/100) against fair (50/100) for PdRu5 Stress-relieved.
Ready to make it?
Upload a CAD file and FabDigit prices the part in PdRu5-H02 and PdRu5 Stress-relieved side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.