FabDigitFabDigit

Precious Metal IC-Ag99.99-H02 vs IC-Ag99.99-H04

Precious Metal · IC-Ag99.99 temper comparison

IC-Ag99.99-H02 and IC-Ag99.99-H04 are two conditions of the same precious metal grade, IC-Ag99.99: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. IC-Ag99.99-H04 is the stronger of the two: yield strength 270 MPa (39.2 ksi) against 175 MPa (25.4 ksi) for IC-Ag99.99-H02, about 54% more; tensile strength follows at 310 MPa (45 ksi) vs 235 MPa (34.1 ksi). In exchange, IC-Ag99.99-H02 is the more ductile: elongation 12% versus 4% for IC-Ag99.99-H04, and IC-Ag99.99-H04 is harder (82 HB vs 58 HB). IC-Ag99.99-H02 runs hotter in service (180°C vs 150°C continuous).

IC-Ag99.99-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

IC-Ag99.99-H04Choose it when strength drives the design.

IC-Ag99.99-H02 vs IC-Ag99.99-H04: properties

IC-Ag99.99-H02IC-Ag99.99-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

235 MPa34.1 ksi
310 MPa45 ksi

Yield Strength (0.2% offset)

175 MPa25.4 ksi
270 MPa39.2 ksi

Elongation at Break

12%
4%

Reduction in Area

40%
80%

Shear Strength

160 MPa23.2 ksi
190 MPa27.6 ksi

Hardness, Brinell

58 HB
82 HB

Hardness, Vickers

62 HV
88 HV

Same in both: Elastic (Young's) Modulus 76 GPa11 Msi · Shear Modulus 29 GPa4.2 Msi · Bulk Modulus 100 GPa14.5 Msi · Poisson's Ratio 0.37 · Fatigue Strength (Endurance Limit) 90 MPa13.1 ksi

Physical

Density and transition temperatures.

Same in both: Density 10.49 g/cm³0.38 lb/in³ · Melting Point (Solidus) 962°C1,763 °F · Liquidus Temperature 962°C1,763 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

180°C356 °F
150°C302 °F

Same in both: Thermal Conductivity 420 W/m·K243 BTU/hr·ft·°F · Specific Heat Capacity 235 J/kg·K0.06 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.5 µm/m·K10.8 µin/in·°F · Latent Heat of Fusion 105 J/g45.1 BTU/lb · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

104 % IACS
103 % IACS

Electrical Resistivity

1.66×10⁻⁸ Ω·m0.654 µΩ·in
1.59×10⁻⁸ Ω·m0.626 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) 0.05 V · Corrosion Resistance 78 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

50%
40%

Weldability

60 / 100
65 / 100

Formability (cold)

70 / 100
40 / 100

Same in both: Machinability 55 / 100 · Castability 85 / 100 · Brazeability / Solderability 95 / 100 · Polishability 95 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 1,500 MJ/kg644,885 BTU/lb · Embodied Carbon (primary production) 110 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

50100200500101520Density (g/cm³)Yield strength (MPa) — log scaleIC-Ag99.99

IC-Ag99.99-H02 vs IC-Ag99.99-H04 — frequently asked

Is IC-Ag99.99-H04 stronger than IC-Ag99.99-H02?

Yes. IC-Ag99.99-H04 has a typical yield strength of 270 MPa (39.2 ksi) against 175 MPa (25.4 ksi) for IC-Ag99.99-H02 — about 54% more. Tensile strength is 310 MPa (45 ksi) vs 235 MPa (34.1 ksi).

Which condition does FabDigit quote by default, H02 or H04?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which welds better, IC-Ag99.99-H02 or IC-Ag99.99-H04?

IC-Ag99.99-H04. Its weldability rates good (65/100) against good (60/100) for IC-Ag99.99-H02.

Ready to make it?

Upload a CAD file and FabDigit prices the part in IC-Ag99.99-H02 and IC-Ag99.99-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.