FabDigitFabDigit

POM GF30 vs POM HF

Polymer · POM grade comparison

POM GF30 and POM HF are two grades of the same polymer grade, POM: GF30 (30% glass fiber reinforced) versus HF (high-flow / thin-wall injection grade). The chemistry is identical, so every difference below comes from the condition. POM GF30 is the stronger of the two: tensile strength 135 MPa (19.6 ksi) against 61 MPa (8.85 ksi) for POM HF, about 121% more. In exchange, POM HF is the more ductile: elongation 20% versus 2.5% for POM GF30. POM HF is lighter (1.41 g/cm³ vs 1.63 g/cm³ for POM GF30) and POM GF30 is stiffer (9.5 GPa vs 2.9 GPa). On the shop floor, POM HF machines more easily (excellent vs good) and POM GF30 welds better (good vs fair).

POM GF30Choose it when strength drives the design, or when it will be welded.

POM HFChoose it when the part is bent, formed or impact-loaded, or when weight is the constraint.

POM GF30 vs POM HF: properties

POM GF30POM HF

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

9.5 GPa1.4 Msi
2.9 GPa0.42 Msi

Tensile Strength (Ultimate)

135 MPa19.6 ksi
61 MPa8.8 ksi

Yield Strength (0.2% offset)

62 MPa9 ksi
60 MPa8.7 ksi

Elongation at Break

2.5%
20%

Compressive Strength

105 MPa15.2 ksi
103 MPa14.9 ksi

Flexural Strength

195 MPa28.3 ksi
88 MPa12.8 ksi

Flexural Modulus

8.8 GPa1.3 Msi
2.7 GPa0.39 Msi

Shear Strength

55 MPa8 ksi
54 MPa7.8 ksi

Fracture Toughness (K_IC)

4 MPa·√m3.6 ksi·√in
3.8 MPa·√m3.5 ksi·√in

Izod Impact, Notched

75 J/m1.4 ft·lbf/in
55 J/m1 ft·lbf/in

Hardness, Rockwell M

80 HRM
79 HRM

Same in both: Shear Modulus 1.1 GPa0.15 Msi · Bulk Modulus 3 GPa0.45 Msi · Poisson's Ratio 0.35 · Compressive Modulus 2.7 GPa0.39 Msi · Hardness, Shore D 81 Shore D · Hardness, Rockwell R 120 HRR

Physical

Density and transition temperatures.

Density

1.63 g/cm³0.06 lb/in³
1.41 g/cm³0.05 lb/in³

Same in both: Melting Temperature (Tm) 166°C331 °F · Glass Transition (Tg) -60°C-76 °F · Water Absorption (24 h) 0.22% · Water Absorption (Saturation) 0.8%

Thermal

How each material carries heat and how hot it can run.

Thermal Expansion (CTE, 20–100 °C)

35 µm/m·K19.4 µin/in·°F
110 µm/m·K61.1 µin/in·°F

Heat Deflection Temp. @ 0.45 MPa

158°C316 °F
156°C313 °F

Heat Deflection Temp. @ 1.8 MPa

163°C325 °F
102°C216 °F

Vicat Softening Point (B50)

160°C320 °F
158°C316 °F

Same in both: Thermal Conductivity 0.31 W/m·K0.18 BTU/hr·ft·°F · Specific Heat Capacity 1,470 J/kg·K0.35 BTU/lb·°F · Max Service Temperature (continuous) 95°C203 °F · Min Service Temperature -40°C-40 °F · Limiting Oxygen Index 15% · Max Service Temperature (short-term) 140°C284 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Resistivity 1×10¹² Ω·m3.94×10¹⁹ µΩ·in · Dielectric Strength 20 kV/mm508 V/mil · Dielectric Constant (1 MHz) 3.7 · Dissipation Factor (1 MHz) 0.005 · Volume Resistivity 1×10¹⁴ Ω·cm · Surface Resistivity 1×10¹⁴ Ω · Comparative Tracking Index (CTI) 600 V

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 70 / 100 · UV / Weathering Resistance 30 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
88 / 100

Weldability

55 / 100
40 / 100

Formability (cold)

40 / 100
25 / 100

Mold Shrinkage

0.6%
2.1%

Melt Flow Rate

9 g/10 min
27 g/10 min

Processing Melt Temperature (typ.)

200°C392 °F
195°C383 °F

Same in both: Polishability 70 / 100 · Mold Temperature (typ.) 85°C185 °F

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 100 MJ/kg42,992 BTU/lb · Embodied Carbon (primary production) 4.5 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 0%

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scalePOM

POM GF30 vs POM HF — frequently asked

Is POM GF30 stronger than POM HF?

Yes. POM GF30 has a typical tensile strength of 135 MPa (19.6 ksi) against 61 MPa (8.85 ksi) for POM HF — about 121% more.

Which grade does FabDigit quote by default, GF30 or HF?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, POM GF30 or POM HF?

POM HF. Its machinability rates excellent (88/100) against good (55/100) for POM GF30; for welding the order is POM GF30 first (good, 55/100) then POM HF (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in POM GF30 and POM HF side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.