FabDigitFabDigit

LCP Type III GF30 vs LCP Type III GFMF

Polymer · LCP Type III grade comparison

LCP Type III GF30 and LCP Type III GFMF are two grades of the same polymer grade, LCP Type III: GF30 (30 % glass-fibre reinforced) versus GFMF (GF/MF hybrid). The chemistry is identical, so every difference below comes from the condition. LCP Type III GF30 is the stronger of the two: tensile strength 160 MPa (23.2 ksi) against 130 MPa (18.9 ksi) for LCP Type III GFMF, about 23% more. LCP Type III GF30 is the more ductile: elongation 1.8% versus 1.6% for LCP Type III GFMF. LCP Type III GF30 is lighter (1.62 g/cm³ vs 1.7 g/cm³ for LCP Type III GFMF) and LCP Type III GFMF runs hotter in service (200°C vs 180°C continuous). On the shop floor, LCP Type III GF30 welds better (30 vs 20 out of 100).

LCP Type III GF30Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

LCP Type III GFMFChoose it when the part sees heat.

LCP Type III GF30 vs LCP Type III GFMF: properties

LCP Type III GF30LCP Type III GFMF

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

160 MPa23.2 ksi
130 MPa18.9 ksi

Elongation at Break

1.8%
1.6%

Compressive Strength

65 MPa9.4 ksi
110 MPa16 ksi

Flexural Strength

200 MPa29 ksi
175 MPa25.4 ksi

Flexural Modulus

13.5 GPa2 Msi
14 GPa2 Msi

Shear Strength

55 MPa8 ksi
70 MPa10.2 ksi

Izod Impact, Notched

100 J/m1.9 ft·lbf/in
80 J/m1.5 ft·lbf/in

Hardness, Shore D

88 Shore D
90 Shore D

Hardness, Rockwell M

72 HRM
85 HRM

Same in both: Elastic (Young's) Modulus 14 GPa2 Msi · Shear Modulus 1.2 GPa0.17 Msi · Poisson's Ratio 0.36

Physical

Density and transition temperatures.

Density

1.62 g/cm³0.06 lb/in³
1.7 g/cm³0.06 lb/in³

Same in both: Melting Temperature (Tm) 285°C545 °F · Glass Transition (Tg) 105°C221 °F · Water Absorption (24 h) 0.02% · Water Absorption (Saturation) 0.06%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

0.4 W/m·K0.23 BTU/hr·ft·°F
0.45 W/m·K0.26 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

12 µm/m·K6.7 µin/in·°F
15 µm/m·K8.3 µin/in·°F

Max Service Temperature (continuous)

180°C356 °F
200°C392 °F

Heat Deflection Temp. @ 0.45 MPa

250°C482 °F
240°C464 °F

Heat Deflection Temp. @ 1.8 MPa

215°C419 °F
210°C410 °F

Limiting Oxygen Index

38%
40%

Same in both: Specific Heat Capacity 1,200 J/kg·K0.29 BTU/lb·°F · Min Service Temperature -50°C-58 °F · Max Service Temperature (short-term) 230°C446 °F

Electrical

Conductivity and insulation.

Dielectric Constant (1 MHz)

3.9
3.4

Same in both: Electrical Resistivity 1×10¹³ Ω·m3.94×10²⁰ µΩ·in · Dielectric Strength 35 kV/mm889 V/mil · Dissipation Factor (1 MHz) 0.004 · Volume Resistivity 1×10¹⁵ Ω·cm · Surface Resistivity 1×10¹⁵ Ω · Comparative Tracking Index (CTI) 200 V

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 92 / 100 · UV / Weathering Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
35 / 100

Weldability

30 / 100
20 / 100

Formability (cold)

20 / 100
10 / 100

Mold Shrinkage

0.1%
0.12%

Melt Flow Rate

40 g/10 min
25 g/10 min

Same in both: Polishability 40 / 100 · Processing Melt Temperature (typ.) 310°C590 °F · Mold Temperature (typ.) 90°C194 °F

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 180 MJ/kg77,386 BTU/lb · Embodied Carbon (primary production) 8.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 0%

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scale

LCP Type III GF30 vs LCP Type III GFMF — frequently asked

Is LCP Type III GF30 stronger than LCP Type III GFMF?

Yes. LCP Type III GF30 has a typical tensile strength of 160 MPa (23.2 ksi) against 130 MPa (18.9 ksi) for LCP Type III GFMF — about 23% more.

Which grade does FabDigit quote by default, GF30 or GFMF?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, LCP Type III GF30 or LCP Type III GFMF?

LCP Type III GF30, by a small margin. Both rate fair for machinability — 40/100 against 35/100 for LCP Type III GFMF; for welding the order is LCP Type III GF30 first (poor, 30/100) then LCP Type III GFMF (poor, 20/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in LCP Type III GF30 and LCP Type III GFMF side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.