LCP Type III GF15 and LCP Type III GF30 are two grades of the same polymer grade, LCP Type III: GF15 (15 % glass-fibre reinforced) versus GF30 (30 % glass-fibre reinforced). The chemistry is identical, so every difference below comes from the condition. LCP Type III GF15 is the more ductile: elongation 2.5% versus 1.8% for LCP Type III GF30. LCP Type III GF15 is lighter (1.52 g/cm³ vs 1.62 g/cm³ for LCP Type III GF30) and LCP Type III GF30 is stiffer (14 GPa vs 10 GPa).

LCP Type III GF15Choose it when the part is bent, formed or impact-loaded, or when weight is the constraint.

LCP Type III GF15 vs LCP Type III GF30: properties

LCP Type III GF15LCP Type III GF30

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

10 GPa1.5 Msi
14 GPa2 Msi

Tensile Strength (Ultimate)

155 MPa22.5 ksi
160 MPa23.2 ksi

Elongation at Break

2.5%
1.8%

Flexural Strength

175 MPa25.4 ksi
200 MPa29 ksi

Flexural Modulus

11.5 GPa1.7 Msi
13.5 GPa2 Msi

Izod Impact, Notched

130 J/m2.4 ft·lbf/in
100 J/m1.9 ft·lbf/in

Same in both: Shear Modulus 1.2 GPa0.17 Msi · Poisson's Ratio 0.36 · Compressive Strength 65 MPa9.4 ksi · Shear Strength 55 MPa8 ksi · Hardness, Shore D 88 Shore D · Hardness, Rockwell M 72 HRM

Physical

Density and transition temperatures.

Density

1.52 g/cm³0.05 lb/in³
1.62 g/cm³0.06 lb/in³

Same in both: Melting Temperature (Tm) 285°C545 °F · Glass Transition (Tg) 105°C221 °F · Water Absorption (24 h) 0.02% · Water Absorption (Saturation) 0.06%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

0.3 W/m·K0.17 BTU/hr·ft·°F
0.4 W/m·K0.23 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

10 µm/m·K5.6 µin/in·°F
12 µm/m·K6.7 µin/in·°F

Max Service Temperature (continuous)

170°C338 °F
180°C356 °F

Heat Deflection Temp. @ 0.45 MPa

225°C437 °F
250°C482 °F

Heat Deflection Temp. @ 1.8 MPa

200°C392 °F
215°C419 °F

Same in both: Specific Heat Capacity 1,200 J/kg·K0.29 BTU/lb·°F · Min Service Temperature -50°C-58 °F · Limiting Oxygen Index 38% · Max Service Temperature (short-term) 230°C446 °F

Electrical

Conductivity and insulation.

Dielectric Constant (1 MHz)

3.4
3.9

Same in both: Electrical Resistivity 1×10¹³ Ω·m3.94×10²⁰ µΩ·in · Dielectric Strength 35 kV/mm889 V/mil · Dissipation Factor (1 MHz) 0.004 · Volume Resistivity 1×10¹⁵ Ω·cm · Surface Resistivity 1×10¹⁵ Ω · Comparative Tracking Index (CTI) 200 V

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 92 / 100 · UV / Weathering Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

48 / 100
40 / 100

Mold Shrinkage

0.12%
0.1%

Same in both: Weldability 30 / 100 · Formability (cold) 20 / 100 · Polishability 40 / 100 · Melt Flow Rate 40 g/10 min · Processing Melt Temperature (typ.) 310°C590 °F · Mold Temperature (typ.) 90°C194 °F

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 180 MJ/kg77,386 BTU/lb · Embodied Carbon (primary production) 8.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 0%

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scale

LCP Type III GF15 vs LCP Type III GF30 — frequently asked

What is the difference between LCP Type III GF15 and LCP Type III GF30?

LCP Type III GF15 and LCP Type III GF30 are two grades of the same polymer grade, LCP Type III: GF15 (15 % glass-fibre reinforced) versus GF30 (30 % glass-fibre reinforced). The chemistry is identical, so every difference below comes from the condition. LCP Type III GF15 is the more ductile: elongation 2.5% versus 1.8% for LCP Type III GF30.

Which grade does FabDigit quote by default, GF15 or GF30?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, LCP Type III GF15 or LCP Type III GF30?

LCP Type III GF15, by a small margin. Both rate fair for machinability — 48/100 against 40/100 for LCP Type III GF30.

Ready to make it?

Upload a CAD file and FabDigit prices the part in LCP Type III GF15 and LCP Type III GF30 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.