FabDigitFabDigit

C578 Type VI vs XPS 300

Polymer · grade comparison

C578 Type VI and XPS 300 are both polymer grades. C578 Type VI is the stronger of the two: tensile strength 0.48 MPa (0.0696 ksi) against 0.45 MPa (0.0653 ksi) for XPS 300, about 7% more. C578 Type VI is lighter (0.03 g/cm³ vs 0.04 g/cm³ for XPS 300) and C578 Type VI is stiffer (0.02 GPa vs 0.02 GPa).

C578 Type VIChoose it when strength drives the design, or when weight is the constraint.

C578 Type VI vs XPS 300: properties

C578 Type VIXPS 300

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

0.02 GPa0 Msi
0.02 GPa0 Msi

Shear Modulus

0.01 GPa0 Msi
—

Poisson's Ratio

0.2
0.3

Tensile Strength (Ultimate)

0.48 MPa0.07 ksi
0.45 MPa0.07 ksi

Compressive Strength

0.31 MPa0.04 ksi
0.32 MPa0.05 ksi

Compressive Modulus

0.02 GPa0 Msi
0.01 GPa0 Msi

Flexural Strength

0.45 MPa0.07 ksi
0.55 MPa0.08 ksi

Shear Strength

0.26 MPa0.04 ksi
0.25 MPa0.04 ksi

Yield Strength (0.2% offset)

—
0.3 MPa0.04 ksi

Elongation at Break

—
3%

Flexural Modulus

—
0.01 GPa0 Msi

Physical

Density and transition temperatures.

Density

0.03 g/cm³0 lb/in³
0.04 g/cm³0 lb/in³

Water Absorption (24 h)

0.1%
0.2%

Same in both: Glass Transition (Tg) 100°C212 °F · Water Absorption (Saturation) 0.5%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

0.03 W/m·K0.02 BTU/hr·ft·°F
0.03 W/m·K0.02 BTU/hr·ft·°F

Specific Heat Capacity

1,400 J/kg·K0.33 BTU/lb·°F
1,450 J/kg·K0.35 BTU/lb·°F

Max Service Temperature (continuous)

74°C165 °F
75°C167 °F

Limiting Oxygen Index

26%
25%

Vicat Softening Point (B50)

—
95°C203 °F

Same in both: Thermal Expansion (CTE, 20–100 °C) 70 µm/m·K38.9 µin/in·°F · Min Service Temperature -50°C-58 °F · Max Service Temperature (short-term) 85°C185 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

—
1×10¹⁴ Ω·m3.94×10²¹ µΩ·in

Same in both: Dielectric Constant (1 MHz) 1.07 · Volume Resistivity 1×10¹⁶ Ω·cm

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 85 / 100 · UV / Weathering Resistance 15 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

15 / 100
10 / 100

Weldability

—
15 / 100

Same in both: Machinability 92 / 100 · Processing Melt Temperature (typ.) 190°C374 °F

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

105 MJ/kg45,142 BTU/lb
100 MJ/kg42,992 BTU/lb

Embodied Carbon (primary production)

4.8 kg CO₂/kg
3.2 kg CO₂/kg

Typical Recycled Content

10%
15%

Embodied Water

—
130 L/kg15.6 gal/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

16 kN·m/kg
13 kN·m/kg

Specific Stiffness (E / density)

0.6 MN·m/kg
0.4 MN·m/kg

Same in both: Thermal Diffusivity 0.7 mm²/s · Thermal Shock Resistance Index 0

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scaleXPS 300

Manufacturing and finishing

CapabilityC578 Type VIXPS 300
Default condition——
Relative cost$$ Standard$$ Standard
Min. machined wall——
Best machined surface——

C578 Type VI vs XPS 300 — frequently asked

Is C578 Type VI stronger than XPS 300?

Yes. C578 Type VI has a typical tensile strength of 0.48 MPa (0.0696 ksi) against 0.45 MPa (0.0653 ksi) for XPS 300 — about 7% more.

Which is cheaper, C578 Type VI or XPS 300?

Both sit in the same relative cost tier ($$, standard); the part price will be decided by machining time, tolerance and quantity rather than by the material.

When should I choose C578 Type VI over XPS 300?

Pick C578 Type VI when strength drives the design, or when weight is the constraint.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C578 Type VI and XPS 300 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.