FabDigitFabDigit

Nickel Alloy Ni-Span-C 902-CD vs Ni-Span-C 902 HF+AGE

Nickel Alloy · Ni-Span-C 902 temper comparison

Ni-Span-C 902-CD and Ni-Span-C 902 HF+AGE are two conditions of the same nickel alloy grade, Ni-Span-C 902: CD (cold drawn) versus HF+AGE (hot Finished + Solution Treated + Aged bar/forging). The chemistry is identical, so every difference below comes from the condition. Ni-Span-C 902-CD is the stronger of the two: yield strength 930 MPa (135 ksi) against 655 MPa (95 ksi) for Ni-Span-C 902 HF+AGE, about 42% more; tensile strength follows at 1,100 MPa (160 ksi) vs 1,000 MPa (145 ksi). In exchange, Ni-Span-C 902 HF+AGE is the more ductile: elongation 22% versus 8% for Ni-Span-C 902-CD, and Ni-Span-C 902-CD is harder (105 HRB vs 85 HRB). Ni-Span-C 902 HF+AGE runs hotter in service (250°C vs 175°C continuous).

Ni-Span-C 902-CDChoose it when strength drives the design.

Ni-Span-C 902 HF+AGEChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Ni-Span-C 902-CD vs Ni-Span-C 902 HF+AGE: properties

Ni-Span-C 902-CDNi-Span-C 902 HF+AGE

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

183 GPa26.5 Msi
186 GPa27 Msi

Tensile Strength (Ultimate)

1,100 MPa160 ksi
1,000 MPa145 ksi

Yield Strength (0.2% offset)

930 MPa135 ksi
655 MPa95 ksi

Elongation at Break

8%
22%

Reduction in Area

30%
40%

Shear Strength

680 MPa98.6 ksi
650 MPa94.3 ksi

Fatigue Strength (Endurance Limit)

450 MPa65.3 ksi
400 MPa58 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
32 J23.6 ft·lbf

Hardness, Brinell

310 HB
300 HB

Hardness, Rockwell B

105 HRB
85 HRB

Same in both: Shear Modulus 69 GPa10 Msi · Bulk Modulus 150 GPa21.8 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.05 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

13.8 W/m·K8 BTU/hr·ft·°F
14.5 W/m·K8.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
250°C482 °F

Same in both: Specific Heat Capacity 502 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 8 µm/m·K4.4 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

1.7 % IACS
1.8 % IACS

Electrical Resistivity

1.04×10⁻⁶ Ω·m40.9 µΩ·in
9.6×10⁻⁷ Ω·m37.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.4 V · Corrosion Resistance 40 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

26 / 100
22 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
18%

Weldability

45 / 100
40 / 100

Formability (cold)

35 / 100
20 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 115 MJ/kg49,441 BTU/lb · Embodied Carbon (primary production) 8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleNi-Span-C 902

Ni-Span-C 902-CD vs Ni-Span-C 902 HF+AGE — frequently asked

Is Ni-Span-C 902-CD stronger than Ni-Span-C 902 HF+AGE?

Yes. Ni-Span-C 902-CD has a typical yield strength of 930 MPa (135 ksi) against 655 MPa (95 ksi) for Ni-Span-C 902 HF+AGE — about 42% more. Tensile strength is 1,100 MPa (160 ksi) vs 1,000 MPa (145 ksi).

Which condition does FabDigit quote by default, CD or HF+AGE?

ANN is the default Ni-Span-C 902 condition in the FabDigit quote flow (neither CD nor HF+AGE). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, Ni-Span-C 902-CD or Ni-Span-C 902 HF+AGE?

Ni-Span-C 902-CD. Its weldability rates fair (45/100) against fair (40/100) for Ni-Span-C 902 HF+AGE.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Ni-Span-C 902-CD and Ni-Span-C 902 HF+AGE side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.