FabDigitFabDigit

Nickel Alloy Ni-Span-C 902-CD vs Ni-Span-C 902 CW50+AGE

Nickel Alloy · Ni-Span-C 902 temper comparison

Ni-Span-C 902-CD and Ni-Span-C 902 CW50+AGE are two conditions of the same nickel alloy grade, Ni-Span-C 902: CD (cold drawn) versus CW50+AGE (heavily Cold Drawn (≈50 %) + Aged). The chemistry is identical, so every difference below comes from the condition. Ni-Span-C 902 CW50+AGE is the stronger of the two: yield strength 1,400 MPa (203 ksi) against 930 MPa (135 ksi) for Ni-Span-C 902-CD, about 51% more; tensile strength follows at 1,590 MPa (231 ksi) vs 1,100 MPa (160 ksi). In exchange, Ni-Span-C 902-CD is the more ductile: elongation 8% versus 5% for Ni-Span-C 902 CW50+AGE, and Ni-Span-C 902 CW50+AGE is harder (430 HB vs 310 HB). Ni-Span-C 902 CW50+AGE is stiffer (193 GPa vs 183 GPa) and Ni-Span-C 902 CW50+AGE runs hotter in service (200°C vs 175°C continuous). On the shop floor, Ni-Span-C 902-CD machines more easily (26 vs 15 out of 100) and Ni-Span-C 902-CD welds better (fair vs poor).

Ni-Span-C 902-CDChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

Ni-Span-C 902 CW50+AGEChoose it when strength drives the design, or when the part sees heat.

Ni-Span-C 902-CD vs Ni-Span-C 902 CW50+AGE: properties

Ni-Span-C 902-CDNi-Span-C 902 CW50+AGE

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

183 GPa26.5 Msi
193 GPa28 Msi

Tensile Strength (Ultimate)

1,100 MPa160 ksi
1,590 MPa231 ksi

Yield Strength (0.2% offset)

930 MPa135 ksi
1,400 MPa203 ksi

Elongation at Break

8%
5%

Reduction in Area

30%
12%

Shear Strength

680 MPa98.6 ksi
950 MPa138 ksi

Fatigue Strength (Endurance Limit)

450 MPa65.3 ksi
570 MPa82.7 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

310 HB
430 HB

Hardness, Rockwell B

105 HRB
85 HRB

Same in both: Shear Modulus 69 GPa10 Msi · Bulk Modulus 150 GPa21.8 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.05 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

13.8 W/m·K8 BTU/hr·ft·°F
14.2 W/m·K8.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
200°C392 °F

Same in both: Specific Heat Capacity 502 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 8 µm/m·K4.4 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

1.7 % IACS
1.8 % IACS

Electrical Resistivity

1.04×10⁻⁶ Ω·m40.9 µΩ·in
9.6×10⁻⁷ Ω·m37.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

40 / 100
38 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.4 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

26 / 100
15 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
12%

Weldability

45 / 100
30 / 100

Formability (cold)

35 / 100
8 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 115 MJ/kg49,441 BTU/lb · Embodied Carbon (primary production) 8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleNi-Span-C 902

Ni-Span-C 902-CD vs Ni-Span-C 902 CW50+AGE — frequently asked

Is Ni-Span-C 902 CW50+AGE stronger than Ni-Span-C 902-CD?

Yes. Ni-Span-C 902 CW50+AGE has a typical yield strength of 1,400 MPa (203 ksi) against 930 MPa (135 ksi) for Ni-Span-C 902-CD — about 51% more. Tensile strength is 1,590 MPa (231 ksi) vs 1,100 MPa (160 ksi).

Which condition does FabDigit quote by default, CD or CW50+AGE?

ANN is the default Ni-Span-C 902 condition in the FabDigit quote flow (neither CD nor CW50+AGE). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Ni-Span-C 902-CD or Ni-Span-C 902 CW50+AGE?

Ni-Span-C 902-CD, by a small margin. Both rate poor for machinability — 26/100 against 15/100 for Ni-Span-C 902 CW50+AGE; for welding the order is Ni-Span-C 902-CD first (fair, 45/100) then Ni-Span-C 902 CW50+AGE (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Ni-Span-C 902-CD and Ni-Span-C 902 CW50+AGE side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.