FabDigitFabDigit

Nickel Alloy N08221-ANN vs N08221-CW

Nickel Alloy · N08221 temper comparison

N08221-ANN and N08221-CW are two conditions of the same nickel alloy grade, N08221: ANN (annealed) versus CW (cold worked). The chemistry is identical, so every difference below comes from the condition. N08221-CW is the stronger of the two: yield strength 650 MPa (94.3 ksi) against 300 MPa (43.5 ksi) for N08221-ANN, about 117% more; tensile strength follows at 860 MPa (125 ksi) vs 650 MPa (94.3 ksi). In exchange, N08221-ANN is the more ductile: elongation 48% versus 22% for N08221-CW, and N08221-CW is harder (250 HB vs 170 HB).

N08221-ANNChoose it when the part is bent, formed or impact-loaded.

N08221-CWChoose it when strength drives the design.

N08221-ANN vs N08221-CW: properties

N08221-ANNN08221-CW

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

650 MPa94.3 ksi
860 MPa125 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
650 MPa94.3 ksi

Elongation at Break

48%
22%

Reduction in Area

60%
45%

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
360 MPa52.2 ksi

Hardness, Brinell

170 HB
250 HB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.31 · Shear Strength 430 MPa62.4 ksi · Charpy V-Notch Impact (RT) 200 J148 ft·lbf · Hardness, Rockwell B 87 HRB

Physical

Density and transition temperatures.

Same in both: Density 8.1 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,330°C2,426 °F · Liquidus Temperature 1,385°C2,525 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 11 W/m·K6.4 BTU/hr·ft·°F · Specific Heat Capacity 450 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13.6 µm/m·K7.6 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Max Service Temperature (continuous) 500°C932 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.5 % IACS · Electrical Resistivity 1.15×10⁻⁶ Ω·m45.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

84 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
30 / 100

Formability (cold)

70 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 15% · Weldability 78 / 100 · Castability 40 / 100 · Brazeability / Solderability 60 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleN08221

N08221-ANN vs N08221-CW — frequently asked

Is N08221-CW stronger than N08221-ANN?

Yes. N08221-CW has a typical yield strength of 650 MPa (94.3 ksi) against 300 MPa (43.5 ksi) for N08221-ANN — about 117% more. Tensile strength is 860 MPa (125 ksi) vs 650 MPa (94.3 ksi).

Which condition does FabDigit quote by default, ANN or CW?

ANN is the default N08221 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, N08221-ANN or N08221-CW?

N08221-CW, by a small margin. Both rate poor for machinability — 30/100 against 24/100 for N08221-ANN.

Ready to make it?

Upload a CAD file and FabDigit prices the part in N08221-ANN and N08221-CW side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.