FabDigitFabDigit

Nickel Alloy N06255-CD vs N06255-SA

Nickel Alloy · N06255 temper comparison

N06255-CD and N06255-SA are two conditions of the same nickel alloy grade, N06255: CD (cold drawn) versus SA (solution annealed). The chemistry is identical, so every difference below comes from the condition. N06255-CD is the stronger of the two: yield strength 700 MPa (102 ksi) against 355 MPa (51.5 ksi) for N06255-SA, about 97% more; tensile strength follows at 950 MPa (138 ksi) vs 760 MPa (110 ksi). In exchange, N06255-SA is the more ductile: elongation 55% versus 25% for N06255-CD, and N06255-CD is harder (290 HB vs 195 HB). N06255-SA runs hotter in service (650°C vs 480°C continuous).

N06255-CDChoose it when strength drives the design.

N06255-SAChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

N06255-CD vs N06255-SA: properties

N06255-CDN06255-SA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

950 MPa138 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

700 MPa102 ksi
355 MPa51.5 ksi

Elongation at Break

25%
55%

Reduction in Area

40%
60%

Shear Strength

570 MPa82.7 ksi
480 MPa69.6 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
300 MPa43.5 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
200 J148 ft·lbf

Hardness, Brinell

290 HB
195 HB

Hardness, Vickers

305 HV
205 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 171 GPa24.8 Msi · Poisson's Ratio 0.31 · Hardness, Rockwell B 89 HRB

Physical

Density and transition temperatures.

Same in both: Density 8.6 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,330°C2,426 °F · Liquidus Temperature 1,385°C2,525 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

480°C896 °F
650°C1,202 °F

Same in both: Thermal Conductivity 10 W/m·K5.8 BTU/hr·ft·°F · Specific Heat Capacity 425 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.4 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1.26×10⁻⁶ Ω·m49.6 µΩ·in
1.25×10⁻⁶ Ω·m49.2 µΩ·in

Same in both: Electrical Conductivity 1.4 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

88 / 100
92 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
20 / 100

Machinability Rating (AISI 1212 = 100 %)

15%
12%

Weldability

78 / 100
85 / 100

Formability (cold)

40 / 100
75 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 60 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 140 MJ/kg60,189 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 400 L/kg47.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleN06255

N06255-CD vs N06255-SA — frequently asked

Is N06255-CD stronger than N06255-SA?

Yes. N06255-CD has a typical yield strength of 700 MPa (102 ksi) against 355 MPa (51.5 ksi) for N06255-SA — about 97% more. Tensile strength is 950 MPa (138 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, CD or SA?

SA is the default N06255 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, N06255-CD or N06255-SA?

N06255-CD, by a small margin. Both rate poor for machinability — 25/100 against 20/100 for N06255-SA; for welding the order is N06255-SA first (excellent, 85/100) then N06255-CD (very good, 78/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in N06255-CD and N06255-SA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.