FabDigitFabDigit

Nickel Alloy N06255-CD vs N06255 HF-A

Nickel Alloy · N06255 temper comparison

N06255-CD and N06255 HF-A are two conditions of the same nickel alloy grade, N06255: CD (cold drawn) versus HF-A (hot finished and solution annealed). The chemistry is identical, so every difference below comes from the condition. N06255-CD is the stronger of the two: yield strength 700 MPa (102 ksi) against 340 MPa (49.3 ksi) for N06255 HF-A, about 106% more; tensile strength follows at 950 MPa (138 ksi) vs 730 MPa (106 ksi). In exchange, N06255 HF-A is the more ductile: elongation 50% versus 25% for N06255-CD, and N06255-CD is harder (290 HB vs 185 HB). N06255 HF-A runs hotter in service (650°C vs 480°C continuous).

N06255-CDChoose it when strength drives the design.

N06255 HF-AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

N06255-CD vs N06255 HF-A: properties

N06255-CDN06255 HF-A

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

950 MPa138 ksi
730 MPa106 ksi

Yield Strength (0.2% offset)

700 MPa102 ksi
340 MPa49.3 ksi

Elongation at Break

25%
50%

Reduction in Area

40%
55%

Shear Strength

570 MPa82.7 ksi
460 MPa66.7 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
290 MPa42.1 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
190 J140 ft·lbf

Hardness, Brinell

290 HB
185 HB

Hardness, Rockwell B

89 HRB
88 HRB

Hardness, Vickers

305 HV
195 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 171 GPa24.8 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 8.6 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,330°C2,426 °F · Liquidus Temperature 1,385°C2,525 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

480°C896 °F
650°C1,202 °F

Same in both: Thermal Conductivity 10 W/m·K5.8 BTU/hr·ft·°F · Specific Heat Capacity 425 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.4 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1.26×10⁻⁶ Ω·m49.6 µΩ·in
1.25×10⁻⁶ Ω·m49.2 µΩ·in

Same in both: Electrical Conductivity 1.4 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

88 / 100
91 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
22 / 100

Machinability Rating (AISI 1212 = 100 %)

15%
13%

Weldability

78 / 100
85 / 100

Formability (cold)

40 / 100
72 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 60 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 140 MJ/kg60,189 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 400 L/kg47.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleN06255

N06255-CD vs N06255 HF-A — frequently asked

Is N06255-CD stronger than N06255 HF-A?

Yes. N06255-CD has a typical yield strength of 700 MPa (102 ksi) against 340 MPa (49.3 ksi) for N06255 HF-A — about 106% more. Tensile strength is 950 MPa (138 ksi) vs 730 MPa (106 ksi).

Which condition does FabDigit quote by default, CD or HF-A?

SA is the default N06255 condition in the FabDigit quote flow (neither CD nor HF-A). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, N06255-CD or N06255 HF-A?

N06255 HF-A. Its weldability rates excellent (85/100) against very good (78/100) for N06255-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in N06255-CD and N06255 HF-A side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.