M-35-1-ANN and M-35-1-F are two conditions of the same nickel alloy grade, M-35-1: ANN (annealed) versus F (as fabricated). The chemistry is identical, so every difference below comes from the condition. M-35-1-F is the stronger of the two: yield strength 205 MPa (29.7 ksi) against 185 MPa (26.8 ksi) for M-35-1-ANN, about 11% more. In exchange, M-35-1-ANN is the more ductile: elongation 40% versus 35% for M-35-1-F, and M-35-1-F is harder (125 HB vs 115 HB).

M-35-1-ANNChoose it when the part is bent, formed or impact-loaded.

M-35-1-FChoose it when strength drives the design.

M-35-1-ANN vs M-35-1-F: properties

M-35-1-ANNM-35-1-F

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
485 MPa70.3 ksi

Yield Strength (0.2% offset)

185 MPa26.8 ksi
205 MPa29.7 ksi

Elongation at Break

40%
35%

Reduction in Area

45%
40%

Shear Strength

320 MPa46.4 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
195 MPa28.3 ksi

Charpy V-Notch Impact (RT)

130 J95.9 ft·lbf
110 J81.1 ft·lbf

Hardness, Brinell

115 HB
125 HB

Hardness, Rockwell B

64 HRB
70 HRB

Same in both: Elastic (Young's) Modulus 150 GPa21.8 Msi · Shear Modulus 57 GPa8.3 Msi · Bulk Modulus 145 GPa21 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 8.84 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,300°C2,372 °F · Liquidus Temperature 1,350°C2,462 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 22 W/m·K12.7 BTU/hr·ft·°F · Specific Heat Capacity 427 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13.9 µm/m·K7.7 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Max Service Temperature (continuous) 480°C896 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3.5 % IACS
3.4 % IACS

Electrical Resistivity

4.9×10⁻⁷ Ω·m19.3 µΩ·in
5.1×10⁻⁷ Ω·m20.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
76 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
30%

Weldability

75 / 100
72 / 100

Same in both: Castability 70 / 100 · Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 125 MJ/kg53,740 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleM-35-1

M-35-1-ANN vs M-35-1-F — frequently asked

Is M-35-1-F stronger than M-35-1-ANN?

Yes. M-35-1-F has a typical yield strength of 205 MPa (29.7 ksi) against 185 MPa (26.8 ksi) for M-35-1-ANN — about 11% more. Tensile strength is 485 MPa (70.3 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, ANN or F?

F is the default M-35-1 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose M-35-1-ANN over M-35-1-F?

Pick M-35-1-ANN when the part is bent, formed or impact-loaded. Pick M-35-1-F when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in M-35-1-ANN and M-35-1-F side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.