FabDigitFabDigit

Nickel Alloy Haynes 282-CW vs Haynes 282-STA

Nickel Alloy · Haynes 282 temper comparison

Haynes 282-CW and Haynes 282-STA are two conditions of the same nickel alloy grade, Haynes 282: CW (cold worked) versus STA (solution treated and aged). The chemistry is identical, so every difference below comes from the condition. Haynes 282-CW is the stronger of the two: yield strength 900 MPa (131 ksi) against 720 MPa (104 ksi) for Haynes 282-STA, about 25% more. In exchange, Haynes 282-STA is the more ductile: elongation 30% versus 20% for Haynes 282-CW, and Haynes 282-STA is harder (310 HB vs 285 HB). Haynes 282-STA runs hotter in service (927°C vs 650°C continuous). On the shop floor, Haynes 282-CW welds better (80 vs 70 out of 100).

Haynes 282-CWChoose it when strength drives the design, or when it will be welded.

Haynes 282-STAChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Haynes 282-CW vs Haynes 282-STA: properties

Haynes 282-CWHaynes 282-STA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Yield Strength (0.2% offset)

900 MPa131 ksi
720 MPa104 ksi

Elongation at Break

20%
30%

Reduction in Area

38%
35%

Fatigue Strength (Endurance Limit)

460 MPa66.7 ksi
470 MPa68.2 ksi

Fracture Toughness (K_IC)

85 MPa·√m77.4 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

75 J55.3 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

285 HB
310 HB

Hardness, Vickers

300 HV
330 HV

Same in both: Elastic (Young's) Modulus 217 GPa31.5 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 190 GPa27.6 Msi · Poisson's Ratio 0.31 · Tensile Strength (Ultimate) 1,150 MPa167 ksi · Shear Strength 700 MPa102 ksi · Hardness, Rockwell B 92 HRB

Physical

Density and transition temperatures.

Same in both: Density 8.27 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,300°C2,372 °F · Liquidus Temperature 1,375°C2,507 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

650°C1,202 °F
927°C1,701 °F

Same in both: Thermal Conductivity 10.2 W/m·K5.9 BTU/hr·ft·°F · Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.6 µm/m·K7 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1.23×10⁻⁶ Ω·m48.4 µΩ·in
1.22×10⁻⁶ Ω·m48 µΩ·in

Same in both: Electrical Conductivity 1.4 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

73 / 100
75 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

18 / 100
14 / 100

Machinability Rating (AISI 1212 = 100 %)

12%
11%

Weldability

80 / 100
70 / 100

Formability (cold)

35 / 100
30 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 60 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 230 MJ/kg98,882 BTU/lb · Embodied Carbon (primary production) 16 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleHaynes 282

Haynes 282-CW vs Haynes 282-STA — frequently asked

Is Haynes 282-CW stronger than Haynes 282-STA?

Yes. Haynes 282-CW has a typical yield strength of 900 MPa (131 ksi) against 720 MPa (104 ksi) for Haynes 282-STA — about 25% more. Tensile strength is 1,150 MPa (167 ksi) vs 1,150 MPa (167 ksi).

Which condition does FabDigit quote by default, CW or STA?

SA is the default Haynes 282 condition in the FabDigit quote flow (neither CW nor STA). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, Haynes 282-CW or Haynes 282-STA?

Haynes 282-CW. Its weldability rates very good (80/100) against very good (70/100) for Haynes 282-STA.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Haynes 282-CW and Haynes 282-STA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.