FabDigitFabDigit

Nickel Alloy ENiCu-7-AW vs ENiCu-7-SR

Nickel Alloy · ENiCu-7 temper comparison

ENiCu-7-AW and ENiCu-7-SR are two conditions of the same nickel alloy grade, ENiCu-7: AW (as-welded deposit) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. ENiCu-7-AW is the stronger of the two: yield strength 290 MPa (42.1 ksi) against 250 MPa (36.3 ksi) for ENiCu-7-SR, about 16% more. In exchange, ENiCu-7-SR is the more ductile: elongation 40% versus 35% for ENiCu-7-AW, and ENiCu-7-AW is harder (165 HB vs 150 HB).

ENiCu-7-AWChoose it when strength drives the design.

ENiCu-7-SRChoose it when the part is bent, formed or impact-loaded.

ENiCu-7-AW vs ENiCu-7-SR: properties

ENiCu-7-AWENiCu-7-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

520 MPa75.4 ksi
500 MPa72.5 ksi

Yield Strength (0.2% offset)

290 MPa42.1 ksi
250 MPa36.3 ksi

Elongation at Break

35%
40%

Reduction in Area

45%
50%

Shear Strength

350 MPa50.8 ksi
338 MPa49 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
190 MPa27.6 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
100 J73.8 ft·lbf

Hardness, Brinell

165 HB
150 HB

Hardness, Rockwell B

84 HRB
78 HRB

Hardness, Vickers

173 HV
157 HV

Same in both: Elastic (Young's) Modulus 179 GPa26 Msi · Shear Modulus 66 GPa9.6 Msi · Bulk Modulus 148 GPa21.5 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,300°C2,372 °F · Liquidus Temperature 1,345°C2,453 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

21.8 W/m·K12.6 BTU/hr·ft·°F
22 W/m·K12.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 427 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13.9 µm/m·K7.7 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Max Service Temperature (continuous) 480°C896 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3.4 % IACS
3.5 % IACS

Electrical Resistivity

5.1×10⁻⁷ Ω·m20.1 µΩ·in
4.9×10⁻⁷ Ω·m19.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.17 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
22%

Formability (cold)

35 / 100
42 / 100

Same in both: Weldability 72 / 100 · Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 125 MJ/kg53,740 BTU/lb · Embodied Carbon (primary production) 10.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleENiCu-7

ENiCu-7-AW vs ENiCu-7-SR — frequently asked

Is ENiCu-7-AW stronger than ENiCu-7-SR?

Yes. ENiCu-7-AW has a typical yield strength of 290 MPa (42.1 ksi) against 250 MPa (36.3 ksi) for ENiCu-7-SR — about 16% more. Tensile strength is 520 MPa (75.4 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, AW or SR?

AW is the default ENiCu-7 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose ENiCu-7-AW over ENiCu-7-SR?

Pick ENiCu-7-AW when strength drives the design. Pick ENiCu-7-SR when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ENiCu-7-AW and ENiCu-7-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.