FabDigitFabDigit

Magnesium Alloy LA141A-F vs LA141A-O

Magnesium Alloy · LA141A temper comparison

LA141A-F and LA141A-O are two conditions of the same magnesium alloy grade, LA141A: F (as fabricated) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. LA141A-F is the stronger of the two: yield strength 110 MPa (16 ksi) against 95 MPa (13.8 ksi) for LA141A-O, about 16% more; tensile strength follows at 145 MPa (21 ksi) vs 132 MPa (19.1 ksi). In exchange, LA141A-O is the more ductile: elongation 25% versus 20% for LA141A-F, and LA141A-F is harder (52 HB vs 45 HB).

LA141A-FChoose it when strength drives the design.

LA141A-OChoose it when the part is bent, formed or impact-loaded.

LA141A-F vs LA141A-O: properties

LA141A-FLA141A-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

145 MPa21 ksi
132 MPa19.1 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
95 MPa13.8 ksi

Elongation at Break

20%
25%

Compressive Strength

105 MPa15.2 ksi
95 MPa13.8 ksi

Shear Strength

98 MPa14.2 ksi
90 MPa13.1 ksi

Fatigue Strength (Endurance Limit)

58 MPa8.4 ksi
55 MPa8 ksi

Hardness, Brinell

52 HB
45 HB

Hardness, Vickers

54 HV
47 HV

Same in both: Elastic (Young's) Modulus 43 GPa6.2 Msi · Shear Modulus 16 GPa2.3 Msi · Bulk Modulus 38 GPa5.5 Msi · Poisson's Ratio 0.36

Physical

Density and transition temperatures.

Same in both: Density 1.35 g/cm³0.05 lb/in³ · Melting Point (Solidus) 570°C1,058 °F · Liquidus Temperature 600°C1,112 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

55 W/m·K31.8 BTU/hr·ft·°F
57 W/m·K32.9 BTU/hr·ft·°F

Max Service Temperature (continuous)

60°C140 °F
65°C149 °F

Same in both: Specific Heat Capacity 1,350 J/kg·K0.32 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 26.5 µm/m·K14.7 µin/in·°F · Latent Heat of Fusion 360 J/g155 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

14 % IACS
14.5 % IACS

Electrical Resistivity

1.2×10⁻⁷ Ω·m4.72 µΩ·in
1.19×10⁻⁷ Ω·m4.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -1.7 V · Corrosion Resistance 8 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

88 / 100
85 / 100

Machinability Rating (AISI 1212 = 100 %)

400%
380%

Weldability

45 / 100
48 / 100

Formability (cold)

85 / 100
92 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 15 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 400 MJ/kg171,969 BTU/lb · Embodied Carbon (primary production) 32 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every magnesium alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

701001502001.41.51.61.71.8Density (g/cm³)Yield strength (MPa) — log scaleLA141A

LA141A-F vs LA141A-O — frequently asked

Is LA141A-F stronger than LA141A-O?

Yes. LA141A-F has a typical yield strength of 110 MPa (16 ksi) against 95 MPa (13.8 ksi) for LA141A-O — about 16% more. Tensile strength is 145 MPa (21 ksi) vs 132 MPa (19.1 ksi).

Which condition does FabDigit quote by default, F or O?

T7 is the default LA141A condition in the FabDigit quote flow (neither F nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose LA141A-F over LA141A-O?

Pick LA141A-F when strength drives the design. Pick LA141A-O when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in LA141A-F and LA141A-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.