FabDigitFabDigit

Magnesium Alloy LA141A-F vs LA141A-H24

Magnesium Alloy · LA141A temper comparison

LA141A-F and LA141A-H24 are two conditions of the same magnesium alloy grade, LA141A: F (as fabricated) versus H24 (strain hardened and partially annealed, half hard). The chemistry is identical, so every difference below comes from the condition. LA141A-H24 is the stronger of the two: yield strength 145 MPa (21 ksi) against 110 MPa (16 ksi) for LA141A-F, about 32% more; tensile strength follows at 165 MPa (23.9 ksi) vs 145 MPa (21 ksi). In exchange, LA141A-F is the more ductile: elongation 20% versus 10% for LA141A-H24, and LA141A-H24 is harder (62 HB vs 52 HB). LA141A-F runs hotter in service (60°C vs 55°C continuous).

LA141A-FChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

LA141A-H24Choose it when strength drives the design.

LA141A-F vs LA141A-H24: properties

LA141A-FLA141A-H24

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

145 MPa21 ksi
165 MPa23.9 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
145 MPa21 ksi

Elongation at Break

20%
10%

Compressive Strength

105 MPa15.2 ksi
140 MPa20.3 ksi

Shear Strength

98 MPa14.2 ksi
108 MPa15.7 ksi

Fatigue Strength (Endurance Limit)

58 MPa8.4 ksi
65 MPa9.4 ksi

Hardness, Brinell

52 HB
62 HB

Hardness, Vickers

54 HV
64 HV

Same in both: Elastic (Young's) Modulus 43 GPa6.2 Msi · Shear Modulus 16 GPa2.3 Msi · Bulk Modulus 38 GPa5.5 Msi · Poisson's Ratio 0.36

Physical

Density and transition temperatures.

Same in both: Density 1.35 g/cm³0.05 lb/in³ · Melting Point (Solidus) 570°C1,058 °F · Liquidus Temperature 600°C1,112 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

55 W/m·K31.8 BTU/hr·ft·°F
53 W/m·K30.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

60°C140 °F
55°C131 °F

Same in both: Specific Heat Capacity 1,350 J/kg·K0.32 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 26.5 µm/m·K14.7 µin/in·°F · Latent Heat of Fusion 360 J/g155 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

14 % IACS
13.5 % IACS

Electrical Resistivity

1.2×10⁻⁷ Ω·m4.72 µΩ·in
1.25×10⁻⁷ Ω·m4.92 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -1.7 V · Corrosion Resistance 8 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

88 / 100
90 / 100

Machinability Rating (AISI 1212 = 100 %)

400%
420%

Weldability

45 / 100
42 / 100

Formability (cold)

85 / 100
65 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 15 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 400 MJ/kg171,969 BTU/lb · Embodied Carbon (primary production) 32 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every magnesium alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

701001502001.41.51.61.71.8Density (g/cm³)Yield strength (MPa) — log scaleLA141A

LA141A-F vs LA141A-H24 — frequently asked

Is LA141A-H24 stronger than LA141A-F?

Yes. LA141A-H24 has a typical yield strength of 145 MPa (21 ksi) against 110 MPa (16 ksi) for LA141A-F — about 32% more. Tensile strength is 165 MPa (23.9 ksi) vs 145 MPa (21 ksi).

Which condition does FabDigit quote by default, F or H24?

T7 is the default LA141A condition in the FabDigit quote flow (neither F nor H24). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose LA141A-F over LA141A-H24?

Pick LA141A-F when the part is bent, formed or impact-loaded, or when the part sees heat. Pick LA141A-H24 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in LA141A-F and LA141A-H24 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.