TBe1.9-TD01 and TBe1.9-TH01 are two conditions of the same copper alloy grade, TBe1.9: TD01 (solution heat treated and cold worked, quarter hard) versus TH01 (TD01 and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. TBe1.9-TH01 is the stronger of the two: yield strength 1,070 MPa (155 ksi) against 450 MPa (65.3 ksi) for TBe1.9-TD01, about 138% more; tensile strength follows at 1,200 MPa (174 ksi) vs 590 MPa (85.6 ksi). In exchange, TBe1.9-TD01 is the more ductile: elongation 20% versus 4% for TBe1.9-TH01, and TBe1.9-TH01 is harder (370 HB vs 165 HB). TBe1.9-TH01 runs hotter in service (200°C vs 150°C continuous) and TBe1.9-TH01 conducts heat better (118 W/m·K vs 105 W/m·K). On the shop floor, TBe1.9-TH01 machines more easily (fair vs poor).

TBe1.9-TD01Choose it when the part is bent, formed or impact-loaded.

TBe1.9-TH01Choose it when strength drives the design, or when the part sees heat.

TBe1.9-TD01 vs TBe1.9-TH01: properties

TBe1.9-TD01TBe1.9-TH01

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

128 GPa18.6 Msi
130 GPa18.9 Msi

Tensile Strength (Ultimate)

590 MPa85.6 ksi
1,200 MPa174 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
1,070 MPa155 ksi

Elongation at Break

20%
4%

Reduction in Area

45%
11%

Compressive Strength

470 MPa68.2 ksi
1,120 MPa162 ksi

Shear Strength

370 MPa53.7 ksi
780 MPa113 ksi

Fatigue Strength (Endurance Limit)

210 MPa30.5 ksi
265 MPa38.4 ksi

Fracture Toughness (K_IC)

60 MPa·√m54.6 ksi·√in
37 MPa·√m33.7 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
7 J5.2 ft·lbf

Hardness, Brinell

165 HB
370 HB

Hardness, Rockwell C

38 HRC
39 HRC

Hardness, Vickers

172 HV
390 HV

Same in both: Shear Modulus 50 GPa7.3 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.26 g/cm³0.3 lb/in³ · Melting Point (Solidus) 865°C1,589 °F · Liquidus Temperature 980°C1,796 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

105 W/m·K60.7 BTU/hr·ft·°F
118 W/m·K68.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.5 µm/m·K9.7 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

17 % IACS
22 % IACS

Electrical Resistivity

1.01×10⁻⁷ Ω·m3.98 µΩ·in
7.8×10⁻⁸ Ω·m3.07 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
30%

Weldability

45 / 100
40 / 100

Formability (cold)

60 / 100
12 / 100

Same in both: Castability 60 / 100 · Brazeability / Solderability 65 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 130 MJ/kg55,890 BTU/lb · Embodied Carbon (primary production) 9 kg CO₂/kg · Embodied Water 400 L/kg47.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleTBe1.9

TBe1.9-TD01 vs TBe1.9-TH01 — frequently asked

Is TBe1.9-TH01 stronger than TBe1.9-TD01?

Yes. TBe1.9-TH01 has a typical yield strength of 1,070 MPa (155 ksi) against 450 MPa (65.3 ksi) for TBe1.9-TD01 — about 138% more. Tensile strength is 1,200 MPa (174 ksi) vs 590 MPa (85.6 ksi).

Which condition does FabDigit quote by default, TD01 or TH01?

TF00 is the default TBe1.9 condition in the FabDigit quote flow (neither TD01 nor TH01). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, TBe1.9-TD01 or TBe1.9-TH01?

TBe1.9-TH01. Its machinability rates fair (45/100) against poor (33/100) for TBe1.9-TD01; for welding the order is TBe1.9-TD01 first (fair, 45/100) then TBe1.9-TH01 (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in TBe1.9-TD01 and TBe1.9-TH01 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.