T2-H08 and T2-H10 are two conditions of the same copper alloy grade, T2: H08 (spring hard) versus H10 (extra spring hard). The chemistry is identical, so every difference below comes from the condition. T2-H10 is the stronger of the two: yield strength 390 MPa (56.6 ksi) against 365 MPa (52.9 ksi) for T2-H08, about 7% more; tensile strength follows at 425 MPa (61.6 ksi) vs 400 MPa (58 ksi). In exchange, T2-H08 is the more ductile: elongation 4% versus 2% for T2-H10, and T2-H10 is harder (125 HV vs 118 HV). T2-H08 runs hotter in service (120°C vs 100°C continuous).

T2-H08Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

T2-H10Choose it when strength drives the design.

T2-H08 vs T2-H10: properties

T2-H08T2-H10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

118 GPa17.1 Msi
120 GPa17.4 Msi

Tensile Strength (Ultimate)

400 MPa58 ksi
425 MPa61.6 ksi

Yield Strength (0.2% offset)

365 MPa52.9 ksi
390 MPa56.6 ksi

Elongation at Break

4%
2%

Reduction in Area

40%
32%

Shear Strength

240 MPa34.8 ksi
255 MPa37 ksi

Fatigue Strength (Endurance Limit)

120 MPa17.4 ksi
125 MPa18.1 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

110 HB
115 HB

Hardness, Vickers

118 HV
125 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.93 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

380 W/m·K220 BTU/hr·ft·°F
378 W/m·K218 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
100°C212 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

96 % IACS
95.5 % IACS

Electrical Resistivity

1.8×10⁻⁸ Ω·m0.707 µΩ·in
1.8×10⁻⁸ Ω·m0.711 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
28%

Formability (cold)

15 / 100
10 / 100

Same in both: Weldability 35 / 100 · Castability 35 / 100 · Brazeability / Solderability 95 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleT2

T2-H08 vs T2-H10 — frequently asked

Is T2-H10 stronger than T2-H08?

Yes. T2-H10 has a typical yield strength of 390 MPa (56.6 ksi) against 365 MPa (52.9 ksi) for T2-H08 — about 7% more. Tensile strength is 425 MPa (61.6 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, H08 or H10?

M is the default T2 condition in the FabDigit quote flow (neither H08 nor H10). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose T2-H08 over T2-H10?

Pick T2-H08 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick T2-H10 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in T2-H08 and T2-H10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.