FabDigitFabDigit

Copper Alloy CuNi2SiCr-AB vs CuNi2SiCr-TF00

Copper Alloy · CuNi2SiCr temper comparison

CuNi2SiCr-AB and CuNi2SiCr-TF00 are two conditions of the same copper alloy grade, CuNi2SiCr: AB (as built (as printed)) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. CuNi2SiCr-TF00 is the stronger of the two: yield strength 530 MPa (76.9 ksi) against 300 MPa (43.5 ksi) for CuNi2SiCr-AB, about 77% more; tensile strength follows at 630 MPa (91.4 ksi) vs 400 MPa (58 ksi). In exchange, CuNi2SiCr-AB is the more ductile: elongation 20% versus 15% for CuNi2SiCr-TF00, and CuNi2SiCr-TF00 is harder (195 HB vs 115 HB). CuNi2SiCr-TF00 runs hotter in service (350°C vs 250°C continuous) and CuNi2SiCr-TF00 conducts heat better (185 W/m·K vs 85 W/m·K).

CuNi2SiCr-ABChoose it when the part is bent, formed or impact-loaded.

CuNi2SiCr-TF00Choose it when strength drives the design, or when the part sees heat.

CuNi2SiCr-AB vs CuNi2SiCr-TF00: properties

CuNi2SiCr-ABCuNi2SiCr-TF00

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
630 MPa91.4 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
530 MPa76.9 ksi

Elongation at Break

20%
15%

Shear Strength

380 MPa55.1 ksi
395 MPa57.3 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
250 MPa36.3 ksi

Hardness, Brinell

115 HB
195 HB

Hardness, Rockwell B

68 HRB
92 HRB

Hardness, Vickers

120 HV
205 HV

Same in both: Elastic (Young's) Modulus 132 GPa19.1 Msi · Shear Modulus 50 GPa7.3 Msi · Bulk Modulus 138 GPa20 Msi · Poisson's Ratio 0.34 · Reduction in Area 30% · Compressive Strength 520 MPa75.4 ksi · Charpy V-Notch Impact (RT) 25 J18.4 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,050°C1,922 °F · Liquidus Temperature 1,090°C1,994 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

85 W/m·K49.1 BTU/hr·ft·°F
185 W/m·K107 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
350°C662 °F

Same in both: Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

18 % IACS
43 % IACS

Electrical Resistivity

9.6×10⁻⁸ Ω·m3.78 µΩ·in
4×10⁻⁸ Ω·m1.57 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
45 / 100

Formability (cold)

45 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 50 / 100 · Castability 50 / 100 · Brazeability / Solderability 70 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCuNi2SiCr

CuNi2SiCr-AB vs CuNi2SiCr-TF00 — frequently asked

Is CuNi2SiCr-TF00 stronger than CuNi2SiCr-AB?

Yes. CuNi2SiCr-TF00 has a typical yield strength of 530 MPa (76.9 ksi) against 300 MPa (43.5 ksi) for CuNi2SiCr-AB — about 77% more. Tensile strength is 630 MPa (91.4 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, AB or TF00?

AB+A is the default CuNi2SiCr condition in the FabDigit quote flow (neither AB nor TF00). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, CuNi2SiCr-AB or CuNi2SiCr-TF00?

CuNi2SiCr-AB, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for CuNi2SiCr-TF00.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CuNi2SiCr-AB and CuNi2SiCr-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.