FabDigitFabDigit

Copper Alloy Cu-OF1-H02 vs Cu-OF1-M

Copper Alloy · Cu-OF1 temper comparison

Cu-OF1-H02 and Cu-OF1-M are two conditions of the same copper alloy grade, Cu-OF1: H02 (half hard) versus M (thermomechanically controlled processed). The chemistry is identical, so every difference below comes from the condition. Cu-OF1-H02 is the stronger of the two: yield strength 230 MPa (33.4 ksi) against 55 MPa (7.98 ksi) for Cu-OF1-M, about 4.2 times as much; tensile strength follows at 300 MPa (43.5 ksi) vs 170 MPa (24.7 ksi). In exchange, Cu-OF1-M is the more ductile: elongation 35% versus 20% for Cu-OF1-H02, and Cu-OF1-H02 is harder (85 HB vs 40 HB). Cu-OF1-H02 is stiffer (123 GPa vs 115 GPa) and Cu-OF1-M runs hotter in service (250°C vs 150°C continuous).

Cu-OF1-H02Choose it when strength drives the design.

Cu-OF1-MChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Cu-OF1-H02 vs Cu-OF1-M: properties

Cu-OF1-H02Cu-OF1-M

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

123 GPa17.8 Msi
115 GPa16.7 Msi

Tensile Strength (Ultimate)

300 MPa43.5 ksi
170 MPa24.7 ksi

Yield Strength (0.2% offset)

230 MPa33.4 ksi
55 MPa8 ksi

Elongation at Break

20%
35%

Shear Strength

185 MPa26.8 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
110 MPa16 ksi

Hardness, Brinell

85 HB
40 HB

Hardness, Rockwell B

36 HRB
45 HRB

Hardness, Vickers

92 HV
42 HV

Same in both: Shear Modulus 46 GPa6.7 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Reduction in Area 60%

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

391 W/m·K226 BTU/hr·ft·°F
394 W/m·K228 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
250°C482 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

100.5 % IACS
101 % IACS

Same in both: Electrical Resistivity 1.72×10⁻⁸ Ω·m0.678 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
27 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
18%

Formability (cold)

65 / 100
80 / 100

Same in both: Weldability 68 / 100 · Castability 55 / 100 · Brazeability / Solderability 95 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-OF1

Cu-OF1-H02 vs Cu-OF1-M — frequently asked

Is Cu-OF1-H02 stronger than Cu-OF1-M?

Yes. Cu-OF1-H02 has a typical yield strength of 230 MPa (33.4 ksi) against 55 MPa (7.98 ksi) for Cu-OF1-M — about 4.2 times as much. Tensile strength is 300 MPa (43.5 ksi) vs 170 MPa (24.7 ksi).

Which condition does FabDigit quote by default, H02 or M?

H04 is the default Cu-OF1 condition in the FabDigit quote flow (neither H02 nor M). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Cu-OF1-H02 over Cu-OF1-M?

Pick Cu-OF1-H02 when strength drives the design. Pick Cu-OF1-M when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-OF1-H02 and Cu-OF1-M side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.