FabDigitFabDigit

Copper Alloy Cu-FRTP-H02 vs Cu-FRTP-H04

Copper Alloy · Cu-FRTP temper comparison

Cu-FRTP-H02 and Cu-FRTP-H04 are two conditions of the same copper alloy grade, Cu-FRTP: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. Cu-FRTP-H04 is the stronger of the two: yield strength 305 MPa (44.2 ksi) against 250 MPa (36.3 ksi) for Cu-FRTP-H02, about 22% more; tensile strength follows at 345 MPa (50 ksi) vs 300 MPa (43.5 ksi). In exchange, Cu-FRTP-H02 is the more ductile: elongation 14% versus 8% for Cu-FRTP-H04, and Cu-FRTP-H04 is harder (100 HB vs 85 HB).

Cu-FRTP-H02Choose it when the part is bent, formed or impact-loaded.

Cu-FRTP-H04Choose it when strength drives the design.

Cu-FRTP-H02 vs Cu-FRTP-H04: properties

Cu-FRTP-H02Cu-FRTP-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

300 MPa43.5 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
305 MPa44.2 ksi

Elongation at Break

14%
8%

Shear Strength

185 MPa26.8 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
115 MPa16.7 ksi

Hardness, Brinell

85 HB
100 HB

Hardness, Rockwell B

45 HRB
55 HRB

Hardness, Vickers

92 HV
108 HV

Same in both: Elastic (Young's) Modulus 122 GPa17.7 Msi · Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Reduction in Area 55%

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

382 W/m·K221 BTU/hr·ft·°F
380 W/m·K220 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

96.5 % IACS
96 % IACS

Same in both: Electrical Resistivity 1.8×10⁻⁸ Ω·m0.709 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

26 / 100
28 / 100

Formability (cold)

60 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 22% · Weldability 35 / 100 · Castability 60 / 100 · Brazeability / Solderability 90 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-FRTP

Cu-FRTP-H02 vs Cu-FRTP-H04 — frequently asked

Is Cu-FRTP-H04 stronger than Cu-FRTP-H02?

Yes. Cu-FRTP-H04 has a typical yield strength of 305 MPa (44.2 ksi) against 250 MPa (36.3 ksi) for Cu-FRTP-H02 — about 22% more. Tensile strength is 345 MPa (50 ksi) vs 300 MPa (43.5 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H04 is the default Cu-FRTP condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Cu-FRTP-H02 over Cu-FRTP-H04?

Pick Cu-FRTP-H02 when the part is bent, formed or impact-loaded. Pick Cu-FRTP-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-FRTP-H02 and Cu-FRTP-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.