FabDigitFabDigit

Copper Alloy Cu-FRTP-H04 vs Cu-FRTP-O60

Copper Alloy · Cu-FRTP temper comparison

Cu-FRTP-H04 and Cu-FRTP-O60 are two conditions of the same copper alloy grade, Cu-FRTP: H04 (full hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. Cu-FRTP-H04 is the stronger of the two: yield strength 305 MPa (44.2 ksi) against 70 MPa (10.2 ksi) for Cu-FRTP-O60, about 4.4 times as much; tensile strength follows at 345 MPa (50 ksi) vs 225 MPa (32.6 ksi). In exchange, Cu-FRTP-O60 is the more ductile: elongation 45% versus 8% for Cu-FRTP-H04, and Cu-FRTP-H04 is harder (100 HB vs 45 HB). Cu-FRTP-O60 runs hotter in service (200°C vs 150°C continuous).

Cu-FRTP-H04Choose it when strength drives the design.

Cu-FRTP-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Cu-FRTP-H04 vs Cu-FRTP-O60: properties

Cu-FRTP-H04Cu-FRTP-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

122 GPa17.7 Msi
117 GPa17 Msi

Tensile Strength (Ultimate)

345 MPa50 ksi
225 MPa32.6 ksi

Yield Strength (0.2% offset)

305 MPa44.2 ksi
70 MPa10.2 ksi

Elongation at Break

8%
45%

Reduction in Area

55%
70%

Shear Strength

200 MPa29 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
75 MPa10.9 ksi

Hardness, Brinell

100 HB
45 HB

Hardness, Vickers

108 HV
50 HV

Same in both: Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Hardness, Rockwell B 55 HRB

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

380 W/m·K220 BTU/hr·ft·°F
388 W/m·K224 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

96 % IACS
98 % IACS

Electrical Resistivity

1.8×10⁻⁸ Ω·m0.709 µΩ·in
1.76×10⁻⁸ Ω·m0.693 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
20 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
20%

Formability (cold)

35 / 100
95 / 100

Same in both: Weldability 35 / 100 · Castability 60 / 100 · Brazeability / Solderability 90 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-FRTP

Cu-FRTP-H04 vs Cu-FRTP-O60 — frequently asked

Is Cu-FRTP-H04 stronger than Cu-FRTP-O60?

Yes. Cu-FRTP-H04 has a typical yield strength of 305 MPa (44.2 ksi) against 70 MPa (10.2 ksi) for Cu-FRTP-O60 — about 4.4 times as much. Tensile strength is 345 MPa (50 ksi) vs 225 MPa (32.6 ksi).

Which condition does FabDigit quote by default, H04 or O60?

H04 is the default Cu-FRTP condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Cu-FRTP-H04 or Cu-FRTP-O60?

Cu-FRTP-H04, by a small margin. Both rate poor for machinability — 28/100 against 20/100 for Cu-FRTP-O60.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-FRTP-H04 and Cu-FRTP-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.