FabDigitFabDigit

Copper Alloy Cu-FRTP-H02 vs Cu-FRTP-H08

Copper Alloy · Cu-FRTP temper comparison

Cu-FRTP-H02 and Cu-FRTP-H08 are two conditions of the same copper alloy grade, Cu-FRTP: H02 (half hard) versus H08 (spring hard). The chemistry is identical, so every difference below comes from the condition. Cu-FRTP-H08 is the stronger of the two: yield strength 360 MPa (52.2 ksi) against 250 MPa (36.3 ksi) for Cu-FRTP-H02, about 44% more; tensile strength follows at 400 MPa (58 ksi) vs 300 MPa (43.5 ksi). In exchange, Cu-FRTP-H02 is the more ductile: elongation 14% versus 3% for Cu-FRTP-H08, and Cu-FRTP-H08 is harder (112 HB vs 85 HB). Cu-FRTP-H02 runs hotter in service (150°C vs 120°C continuous).

Cu-FRTP-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Cu-FRTP-H08Choose it when strength drives the design.

Cu-FRTP-H02 vs Cu-FRTP-H08: properties

Cu-FRTP-H02Cu-FRTP-H08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

300 MPa43.5 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
360 MPa52.2 ksi

Elongation at Break

14%
3%

Shear Strength

185 MPa26.8 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
125 MPa18.1 ksi

Hardness, Brinell

85 HB
112 HB

Hardness, Rockwell B

45 HRB
62 HRB

Hardness, Vickers

92 HV
120 HV

Same in both: Elastic (Young's) Modulus 122 GPa17.7 Msi · Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Reduction in Area 55%

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

382 W/m·K221 BTU/hr·ft·°F
380 W/m·K220 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

96.5 % IACS
95.5 % IACS

Same in both: Electrical Resistivity 1.8×10⁻⁸ Ω·m0.709 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

26 / 100
28 / 100

Formability (cold)

60 / 100
20 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 22% · Weldability 35 / 100 · Castability 60 / 100 · Brazeability / Solderability 90 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-FRTP

Cu-FRTP-H02 vs Cu-FRTP-H08 — frequently asked

Is Cu-FRTP-H08 stronger than Cu-FRTP-H02?

Yes. Cu-FRTP-H08 has a typical yield strength of 360 MPa (52.2 ksi) against 250 MPa (36.3 ksi) for Cu-FRTP-H02 — about 44% more. Tensile strength is 400 MPa (58 ksi) vs 300 MPa (43.5 ksi).

Which condition does FabDigit quote by default, H02 or H08?

H04 is the default Cu-FRTP condition in the FabDigit quote flow (neither H02 nor H08). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Cu-FRTP-H02 over Cu-FRTP-H08?

Pick Cu-FRTP-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick Cu-FRTP-H08 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-FRTP-H02 and Cu-FRTP-H08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.