FabDigitFabDigit

Copper Alloy CC760S-GC vs CC760S-GM

Copper Alloy · CC760S temper comparison

CC760S-GC and CC760S-GM are two conditions of the same copper alloy grade, CC760S: GC (continuously cast bar/tube) versus GM (gravity die (permanent mould) cast). The chemistry is identical, so every difference below comes from the condition. CC760S-GC is the stronger of the two: yield strength 110 MPa (16 ksi) against 100 MPa (14.5 ksi) for CC760S-GM, about 10% more; tensile strength follows at 270 MPa (39.2 ksi) vs 250 MPa (36.3 ksi). In exchange, CC760S-GM is the more ductile: elongation 35% versus 30% for CC760S-GC, and CC760S-GC is harder (65 HB vs 60 HB).

CC760S-GCChoose it when strength drives the design.

CC760S-GMChoose it when the part is bent, formed or impact-loaded.

CC760S-GC vs CC760S-GM: properties

CC760S-GCCC760S-GM

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

270 MPa39.2 ksi
250 MPa36.3 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
100 MPa14.5 ksi

Elongation at Break

30%
35%

Reduction in Area

38%
40%

Shear Strength

175 MPa25.4 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
80 MPa11.6 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

65 HB
60 HB

Hardness, Rockwell B

26 HRB
20 HRB

Hardness, Vickers

68 HV
63 HV

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 40 GPa5.8 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.75 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,000°C1,832 °F · Liquidus Temperature 1,025°C1,877 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 155 W/m·K89.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.7 µm/m·K10.4 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 33 % IACS · Electrical Resistivity 5.2×10⁻⁸ Ω·m2.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

70 / 100
69 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

37 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
30%

Formability (cold)

55 / 100
52 / 100

Same in both: Weldability 45 / 100 · Castability 70 / 100 · Brazeability / Solderability 92 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC760S

CC760S-GC vs CC760S-GM — frequently asked

Is CC760S-GC stronger than CC760S-GM?

Yes. CC760S-GC has a typical yield strength of 110 MPa (16 ksi) against 100 MPa (14.5 ksi) for CC760S-GM — about 10% more. Tensile strength is 270 MPa (39.2 ksi) vs 250 MPa (36.3 ksi).

Which condition does FabDigit quote by default, GC or GM?

GS is the default CC760S condition in the FabDigit quote flow (neither GC nor GM). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC760S-GC over CC760S-GM?

Pick CC760S-GC when strength drives the design. Pick CC760S-GM when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC760S-GC and CC760S-GM side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.