FabDigitFabDigit

Copper Alloy CC753S-GS vs CC753S-GZ

Copper Alloy · CC753S temper comparison

CC753S-GS and CC753S-GZ are two conditions of the same copper alloy grade, CC753S: GS (sand cast) versus GZ (centrifugally cast). The chemistry is identical, so every difference below comes from the condition. CC753S-GZ is the stronger of the two: yield strength 190 MPa (27.6 ksi) against 150 MPa (21.8 ksi) for CC753S-GS, about 27% more; tensile strength follows at 390 MPa (56.6 ksi) vs 320 MPa (46.4 ksi). In exchange, CC753S-GS is the more ductile: elongation 18% versus 15% for CC753S-GZ, and CC753S-GZ is harder (95 HB vs 80 HB).

CC753S-GSChoose it when the part is bent, formed or impact-loaded.

CC753S-GZChoose it when strength drives the design.

CC753S-GS vs CC753S-GZ: properties

CC753S-GSCC753S-GZ

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

95 GPa13.8 Msi
98 GPa14.2 Msi

Tensile Strength (Ultimate)

320 MPa46.4 ksi
390 MPa56.6 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
190 MPa27.6 ksi

Elongation at Break

18%
15%

Reduction in Area

20%
18%

Compressive Strength

320 MPa46.4 ksi
390 MPa56.6 ksi

Shear Strength

230 MPa33.4 ksi
265 MPa38.4 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
110 MPa16 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

80 HB
95 HB

Hardness, Rockwell B

45 HRB
56 HRB

Hardness, Vickers

85 HV
100 HV

Same in both: Shear Modulus 36 GPa5.2 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.4 g/cm³0.3 lb/in³ · Melting Point (Solidus) 880°C1,616 °F · Liquidus Temperature 905°C1,661 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

100 W/m·K57.8 BTU/hr·ft·°F
97 W/m·K56 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

20 % IACS
19 % IACS

Electrical Resistivity

8.6×10⁻⁸ Ω·m3.39 µΩ·in
9.1×10⁻⁸ Ω·m3.58 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

80 / 100
76 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
66%

Same in both: Weldability 25 / 100 · Formability (cold) 15 / 100 · Castability 80 / 100 · Brazeability / Solderability 55 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC753S

CC753S-GS vs CC753S-GZ — frequently asked

Is CC753S-GZ stronger than CC753S-GS?

Yes. CC753S-GZ has a typical yield strength of 190 MPa (27.6 ksi) against 150 MPa (21.8 ksi) for CC753S-GS — about 27% more. Tensile strength is 390 MPa (56.6 ksi) vs 320 MPa (46.4 ksi).

Which condition does FabDigit quote by default, GS or GZ?

GS is the default CC753S condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC753S-GS over CC753S-GZ?

Pick CC753S-GS when the part is bent, formed or impact-loaded. Pick CC753S-GZ when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC753S-GS and CC753S-GZ side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.