CC752S-GC and CC752S-GS are two conditions of the same copper alloy grade, CC752S: GC (continuously cast) versus GS (sand cast). The chemistry is identical, so every difference below comes from the condition. CC752S-GC is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 110 MPa (16 ksi) for CC752S-GS, about 36% more; tensile strength follows at 320 MPa (46.4 ksi) vs 280 MPa (40.6 ksi). In exchange, CC752S-GS is the more ductile: elongation 15% versus 12% for CC752S-GC, and CC752S-GC is harder (90 HB vs 75 HB). CC752S-GC is stiffer (100 GPa vs 95 GPa).

CC752S-GCChoose it when strength drives the design.

CC752S-GSChoose it when the part is bent, formed or impact-loaded.

CC752S-GC vs CC752S-GS: properties

CC752S-GCCC752S-GS

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

100 GPa14.5 Msi
95 GPa13.8 Msi

Tensile Strength (Ultimate)

320 MPa46.4 ksi
280 MPa40.6 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
110 MPa16 ksi

Elongation at Break

12%
15%

Shear Strength

225 MPa32.6 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
90 MPa13.1 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

90 HB
75 HB

Same in both: Shear Modulus 36 GPa5.2 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.45 g/cm³0.31 lb/in³ · Melting Point (Solidus) 880°C1,616 °F · Liquidus Temperature 905°C1,661 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 115 W/m·K66.4 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 24 % IACS · Electrical Resistivity 7.2×10⁻⁸ Ω·m2.83 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
57 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

82 / 100
80 / 100

Formability (cold)

18 / 100
20 / 100

Same in both: Weldability 25 / 100 · Castability 85 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC752S

CC752S-GC vs CC752S-GS — frequently asked

Is CC752S-GC stronger than CC752S-GS?

Yes. CC752S-GC has a typical yield strength of 150 MPa (21.8 ksi) against 110 MPa (16 ksi) for CC752S-GS — about 36% more. Tensile strength is 320 MPa (46.4 ksi) vs 280 MPa (40.6 ksi).

Which condition does FabDigit quote by default, GC or GS?

GS is the default CC752S condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC752S-GC over CC752S-GS?

Pick CC752S-GC when strength drives the design. Pick CC752S-GS when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC752S-GC and CC752S-GS side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.