CC498K-GC and CC498K-GM are two conditions of the same copper alloy grade, CC498K: GC (continuously cast bar/tube) versus GM (permanent (chill) mould cast). The chemistry is identical, so every difference below comes from the condition. CC498K-GC is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 130 MPa (18.9 ksi) for CC498K-GM, about 15% more. CC498K-GC is harder — 78 HB against 72 HB for CC498K-GM — which matters for wear surfaces and threads.

CC498K-GCChoose it when strength drives the design, or when surface hardness matters.

CC498K-GC vs CC498K-GM: properties

CC498K-GCCC498K-GM

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

96 GPa13.9 Msi
92 GPa13.3 Msi

Tensile Strength (Ultimate)

270 MPa39.2 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
130 MPa18.9 ksi

Elongation at Break

12%
13%

Reduction in Area

12%
13%

Shear Strength

205 MPa29.7 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
88 MPa12.8 ksi

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
19 J14 ft·lbf

Hardness, Brinell

78 HB
72 HB

Hardness, Rockwell B

41 HRB
35 HRB

Hardness, Vickers

82 HV
76 HV

Same in both: Shear Modulus 36 GPa5.2 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 855°C1,571 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

62 W/m·K35.8 BTU/hr·ft·°F
60 W/m·K34.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.5 µm/m·K10.3 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

12.5 % IACS
12 % IACS

Electrical Resistivity

1.38×10⁻⁷ Ω·m5.43 µΩ·in
1.44×10⁻⁷ Ω·m5.67 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

82 / 100
80 / 100

Machinability Rating (AISI 1212 = 100 %)

82%
80%

Formability (cold)

12 / 100
10 / 100

Same in both: Weldability 30 / 100 · Castability 85 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 50 MJ/kg21,496 BTU/lb · Embodied Carbon (primary production) 3.5 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC498K

CC498K-GC vs CC498K-GM — frequently asked

Is CC498K-GC stronger than CC498K-GM?

Yes. CC498K-GC has a typical yield strength of 150 MPa (21.8 ksi) against 130 MPa (18.9 ksi) for CC498K-GM — about 15% more. Tensile strength is 270 MPa (39.2 ksi) vs 260 MPa (37.7 ksi).

Which condition does FabDigit quote by default, GC or GM?

GC is the default CC498K condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC498K-GC over CC498K-GM?

Pick CC498K-GC when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC498K-GC and CC498K-GM side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.