FabDigitFabDigit

Copper Alloy CC498K-GC vs CC498K-GS

Copper Alloy · CC498K temper comparison

CC498K-GC and CC498K-GS are two conditions of the same copper alloy grade, CC498K: GC (continuously cast bar/tube) versus GS (sand cast). The chemistry is identical, so every difference below comes from the condition. CC498K-GC is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 110 MPa (16 ksi) for CC498K-GS, about 36% more; tensile strength follows at 270 MPa (39.2 ksi) vs 230 MPa (33.4 ksi). In exchange, CC498K-GS is the more ductile: elongation 15% versus 12% for CC498K-GC, and CC498K-GC is harder (78 HB vs 65 HB). CC498K-GC is stiffer (96 GPa vs 88 GPa).

CC498K-GCChoose it when strength drives the design.

CC498K-GSChoose it when the part is bent, formed or impact-loaded.

CC498K-GC vs CC498K-GS: properties

CC498K-GCCC498K-GS

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

96 GPa13.9 Msi
88 GPa12.8 Msi

Tensile Strength (Ultimate)

270 MPa39.2 ksi
230 MPa33.4 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
110 MPa16 ksi

Elongation at Break

12%
15%

Reduction in Area

12%
14%

Shear Strength

205 MPa29.7 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
80 MPa11.6 ksi

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

78 HB
65 HB

Hardness, Rockwell B

41 HRB
30 HRB

Hardness, Vickers

82 HV
68 HV

Same in both: Shear Modulus 36 GPa5.2 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 855°C1,571 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

62 W/m·K35.8 BTU/hr·ft·°F
59 W/m·K34.1 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.5 µm/m·K10.3 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

12.5 % IACS
12 % IACS

Electrical Resistivity

1.38×10⁻⁷ Ω·m5.43 µΩ·in
1.44×10⁻⁷ Ω·m5.67 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
63 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

82 / 100
80 / 100

Machinability Rating (AISI 1212 = 100 %)

82%
80%

Formability (cold)

12 / 100
10 / 100

Same in both: Weldability 30 / 100 · Castability 85 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 50 MJ/kg21,496 BTU/lb · Embodied Carbon (primary production) 3.5 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC498K

CC498K-GC vs CC498K-GS — frequently asked

Is CC498K-GC stronger than CC498K-GS?

Yes. CC498K-GC has a typical yield strength of 150 MPa (21.8 ksi) against 110 MPa (16 ksi) for CC498K-GS — about 36% more. Tensile strength is 270 MPa (39.2 ksi) vs 230 MPa (33.4 ksi).

Which condition does FabDigit quote by default, GC or GS?

GC is the default CC498K condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC498K-GC over CC498K-GS?

Pick CC498K-GC when strength drives the design. Pick CC498K-GS when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC498K-GC and CC498K-GS side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.