FabDigitFabDigit

Copper Alloy CC493K-GC vs CC493K-GM

Copper Alloy · CC493K temper comparison

CC493K-GC and CC493K-GM are two conditions of the same copper alloy grade, CC493K: GC (continuously cast bar / tube) versus GM (permanent-mould (chill) cast). The chemistry is identical, so every difference below comes from the condition. CC493K-GC is the stronger of the two: yield strength 155 MPa (22.5 ksi) against 145 MPa (21 ksi) for CC493K-GM, about 7% more; tensile strength follows at 300 MPa (43.5 ksi) vs 280 MPa (40.6 ksi). CC493K-GC is harder — 75 HB against 70 HB for CC493K-GM — which matters for wear surfaces and threads.

CC493K-GCChoose it when strength drives the design, or when surface hardness matters.

CC493K-GC vs CC493K-GM: properties

CC493K-GCCC493K-GM

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

300 MPa43.5 ksi
280 MPa40.6 ksi

Yield Strength (0.2% offset)

155 MPa22.5 ksi
145 MPa21 ksi

Elongation at Break

16%
15%

Compressive Strength

480 MPa69.6 ksi
450 MPa65.3 ksi

Shear Strength

195 MPa28.3 ksi
185 MPa26.8 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
85 MPa12.3 ksi

Charpy V-Notch Impact (RT)

12 J8.9 ft·lbf
11 J8.1 ft·lbf

Hardness, Brinell

75 HB
70 HB

Hardness, Rockwell B

40 HRB
34 HRB

Hardness, Vickers

79 HV
73 HV

Same in both: Elastic (Young's) Modulus 97 GPa14.1 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 855°C1,571 °F · Liquidus Temperature 975°C1,787 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

58 W/m·K33.5 BTU/hr·ft·°F
57 W/m·K32.9 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 12 % IACS · Electrical Resistivity 1.44×10⁻⁷ Ω·m5.67 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

59 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 85 / 100 · Machinability Rating (AISI 1212 = 100 %) 80% · Weldability 15 / 100 · Formability (cold) 8 / 100 · Castability 88 / 100 · Brazeability / Solderability 62 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC493K

CC493K-GC vs CC493K-GM — frequently asked

Is CC493K-GC stronger than CC493K-GM?

Yes. CC493K-GC has a typical yield strength of 155 MPa (22.5 ksi) against 145 MPa (21 ksi) for CC493K-GM — about 7% more. Tensile strength is 300 MPa (43.5 ksi) vs 280 MPa (40.6 ksi).

Which condition does FabDigit quote by default, GC or GM?

GC is the default CC493K condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC493K-GC over CC493K-GM?

Pick CC493K-GC when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC493K-GC and CC493K-GM side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.