FabDigitFabDigit

Copper Alloy CC482K-GS vs CC482K-GZ

Copper Alloy · CC482K temper comparison

CC482K-GS and CC482K-GZ are two conditions of the same copper alloy grade, CC482K: GS (sand cast) versus GZ (centrifugal cast). The chemistry is identical, so every difference below comes from the condition. CC482K-GZ is the stronger of the two: yield strength 185 MPa (26.8 ksi) against 150 MPa (21.8 ksi) for CC482K-GS, about 23% more; tensile strength follows at 320 MPa (46.4 ksi) vs 270 MPa (39.2 ksi). In exchange, CC482K-GS is the more ductile: elongation 8% versus 7% for CC482K-GZ, and CC482K-GZ is harder (100 HB vs 85 HB). CC482K-GZ is stiffer (105 GPa vs 98 GPa).

CC482K-GSChoose it when the part is bent, formed or impact-loaded.

CC482K-GZChoose it when strength drives the design.

CC482K-GS vs CC482K-GZ: properties

CC482K-GSCC482K-GZ

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

98 GPa14.2 Msi
105 GPa15.2 Msi

Tensile Strength (Ultimate)

270 MPa39.2 ksi
320 MPa46.4 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
185 MPa26.8 ksi

Elongation at Break

8%
7%

Reduction in Area

10%
9%

Compressive Strength

500 MPa72.5 ksi
580 MPa84.1 ksi

Shear Strength

195 MPa28.3 ksi
230 MPa33.4 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
110 MPa16 ksi

Charpy V-Notch Impact (RT)

9 J6.6 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

85 HB
100 HB

Hardness, Rockwell B

45 HRB
58 HRB

Hardness, Vickers

90 HV
105 HV

Same in both: Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 107 GPa15.5 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 830°C1,526 °F · Liquidus Temperature 990°C1,814 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

45 W/m·K26 BTU/hr·ft·°F
48 W/m·K27.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.5 µm/m·K10.3 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.5 % IACS
11.5 % IACS

Electrical Resistivity

1.64×10⁻⁷ Ω·m6.46 µΩ·in
1.5×10⁻⁷ Ω·m5.91 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

68 / 100
72 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
57%

Same in both: Weldability 25 / 100 · Formability (cold) 8 / 100 · Castability 80 / 100 · Brazeability / Solderability 78 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 65 MJ/kg27,945 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC482K

CC482K-GS vs CC482K-GZ — frequently asked

Is CC482K-GZ stronger than CC482K-GS?

Yes. CC482K-GZ has a typical yield strength of 185 MPa (26.8 ksi) against 150 MPa (21.8 ksi) for CC482K-GS — about 23% more. Tensile strength is 320 MPa (46.4 ksi) vs 270 MPa (39.2 ksi).

Which condition does FabDigit quote by default, GS or GZ?

GC is the default CC482K condition in the FabDigit quote flow (neither GS nor GZ). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC482K-GS over CC482K-GZ?

Pick CC482K-GS when the part is bent, formed or impact-loaded. Pick CC482K-GZ when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC482K-GS and CC482K-GZ side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.