FabDigitFabDigit

Copper Alloy C97600-M04 vs C97600-M07

Copper Alloy · C97600 temper comparison

C97600-M04 and C97600-M07 are two conditions of the same copper alloy grade, C97600: M04 (as pressure die cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C97600-M07 is the stronger of the two: yield strength 195 MPa (28.3 ksi) against 175 MPa (25.4 ksi) for C97600-M04, about 11% more; tensile strength follows at 345 MPa (50 ksi) vs 325 MPa (47.1 ksi). In exchange, C97600-M04 is the more ductile: elongation 18% versus 15% for C97600-M07, and C97600-M07 is harder (90 HB vs 85 HB).

C97600-M04Choose it when the part is bent, formed or impact-loaded.

C97600-M07Choose it when strength drives the design.

C97600-M04 vs C97600-M07: properties

C97600-M04C97600-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

325 MPa47.1 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

175 MPa25.4 ksi
195 MPa28.3 ksi

Elongation at Break

18%
15%

Compressive Strength

345 MPa50 ksi
365 MPa52.9 ksi

Shear Strength

245 MPa35.5 ksi
260 MPa37.7 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
120 MPa17.4 ksi

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
15 J11.1 ft·lbf

Hardness, Brinell

85 HB
90 HB

Hardness, Rockwell B

46 HRB
50 HRB

Same in both: Elastic (Young's) Modulus 138 GPa20 Msi · Shear Modulus 52 GPa7.5 Msi · Bulk Modulus 125 GPa18.1 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.86 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,108°C2,026 °F · Liquidus Temperature 1,143°C2,089 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 26 W/m·K15 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 4.5 % IACS · Electrical Resistivity 3.87×10⁻⁷ Ω·m15.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

68 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

90%
92%

Same in both: Weldability 25 / 100 · Formability (cold) 10 / 100 · Castability 70 / 100 · Brazeability / Solderability 80 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 78 MJ/kg33,534 BTU/lb · Embodied Carbon (primary production) 5.5 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC97600

C97600-M04 vs C97600-M07 — frequently asked

Is C97600-M07 stronger than C97600-M04?

Yes. C97600-M07 has a typical yield strength of 195 MPa (28.3 ksi) against 175 MPa (25.4 ksi) for C97600-M04 — about 11% more. Tensile strength is 345 MPa (50 ksi) vs 325 MPa (47.1 ksi).

Which condition does FabDigit quote by default, M04 or M07?

M01 is the default C97600 condition in the FabDigit quote flow (neither M04 nor M07). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C97600-M04 over C97600-M07?

Pick C97600-M04 when the part is bent, formed or impact-loaded. Pick C97600-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C97600-M04 and C97600-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.